Research on Reactive Power Coordination Control Scheme of Energy Feedback Device in Urban Rail Transit Power Supply System

Journal Title: Urban Mass Transit - Year 2024, Vol 27, Issue 9

Abstract

Objective Currently, the urban rail transit power supply system mainly relies on the main substation SVG (static var compensator) for reactive power compensation. During non-operating hours at night, the medium voltage loop network lines of urban rail transit power supply system are basically unloaded, and the charging reactive power of the lines is high, causing SVG to operate under heavy load for a long time. To alleviate the compensation pressure of SVG, a reactive power coordination control scheme for energy feedback device is proposed, coordinating SVG and the energy feedback devices in the traction substation to jointly participate in reactive power compensation. Method The calculation method of the energy feedback device reactive power compensation capacity is analyzed, and the reactive power coordination control strategy for the SVG and energy feedback device is proposed. Finally, on-site tests on a certain metro line are performed, verifying the correctness of the above strategy. Result & Conclusion When the energy feedback devices of a metro line are all put into use for reactive power compensation, the SVG reactive power compensation capacity can be reduced by 2.6 Mvar to the most, and the total active power loss of the me-dium voltage loop network line can be reduced from 0.7 MW to about 0.5 MW.

Authors and Affiliations

Jiawei ZHAO, Li WANG, Dayun ZOU, Genjun CHEN, Kai XIE

Keywords

Related Articles

Research on Energy Management Method of Fuel Cell Hybrid Power System Based on Improved Equivalent Hydrogen Consumption

Objective Equivalent hydrogen consumption, as a method for optimizing fuel economy, performs poorly in following the state of charge of energy storage systems. Therefore, it is necessary to improve it to achieve dynamic...

Calculation and Analysis of Critical Supporting Pressure for Shield Tunnel Excavation Face in Water-rich Sandy Stratum under Seepage Condition

[Objective] Water-rich sandy stratum is a common geological formation encountered in metro shield tunnel excavation. Seepage may occur under the influence of water pressure differences inside and outside the soil chamber...

Reliability Analysis of Tram Electro-mechanical Braking System Based on Fuzzy Fault Tree

Objective The electro-mechanical braking system architecture of tram is different from that of the traditional braking system, so it is necessary to analyze the system safety and make targeted improvement to its weak lin...

Research on Characteristics of Shanghai Rail Transit Commuter Flow

Objective Shanghai′s rail transit boasts of huge commuter flow, and it is necessary to analyze the spatial distribution, connection and other characteristics of the passengers using urban rail transit for commuting. Meth...

Prediction and Analysis of Earth Pressure Balance Shield Machine Advancing Speed in Limestone Stratum

Objective The advancing speed of shield machine is crucial not only for the tunnel excavation pace but also for the predicting construction schedule and cost. Therefore, it is necessary to predict and analyze the advanci...

Download PDF file
  • EP ID EP744342
  • DOI 10.16037/j.1007-869x.2024.09.034
  • Views 9
  • Downloads 0

How To Cite

Jiawei ZHAO, Li WANG, Dayun ZOU, Genjun CHEN, Kai XIE (2024). Research on Reactive Power Coordination Control Scheme of Energy Feedback Device in Urban Rail Transit Power Supply System. Urban Mass Transit, 27(9), -. https://europub.co.uk/articles/-A-744342