Research on Reactive Power Coordination Control Scheme of Energy Feedback Device in Urban Rail Transit Power Supply System

Journal Title: Urban Mass Transit - Year 2024, Vol 27, Issue 9

Abstract

Objective Currently, the urban rail transit power supply system mainly relies on the main substation SVG (static var compensator) for reactive power compensation. During non-operating hours at night, the medium voltage loop network lines of urban rail transit power supply system are basically unloaded, and the charging reactive power of the lines is high, causing SVG to operate under heavy load for a long time. To alleviate the compensation pressure of SVG, a reactive power coordination control scheme for energy feedback device is proposed, coordinating SVG and the energy feedback devices in the traction substation to jointly participate in reactive power compensation. Method The calculation method of the energy feedback device reactive power compensation capacity is analyzed, and the reactive power coordination control strategy for the SVG and energy feedback device is proposed. Finally, on-site tests on a certain metro line are performed, verifying the correctness of the above strategy. Result & Conclusion When the energy feedback devices of a metro line are all put into use for reactive power compensation, the SVG reactive power compensation capacity can be reduced by 2.6 Mvar to the most, and the total active power loss of the me-dium voltage loop network line can be reduced from 0.7 MW to about 0.5 MW.

Authors and Affiliations

Jiawei ZHAO, Li WANG, Dayun ZOU, Genjun CHEN, Kai XIE

Keywords

Related Articles

Influence of Metro Vehicle Air Compressor Suspension Methods on Modal Parameters and Optimization of Vibration Reduction Forms

[Objective] Air compressor is one of the main sources for metro vehicle vibration excitation. Reasonable modal matching design for air compressor is conducive to reducing the vehicle body vibration and noise, thereby i...

Vibration Reduction Effect of Steel Spring Floating Slabs under Water Immersion Conditions

[Objective] To address the issues of reduced vibration isolation performance of floating slabs under water immersion, it is necessary to study the impact of train operating speed and steel spring isolator stiffness on...

Research and Application of Track Misalignment APM Detection Technology

Objective In order to solve the problems of low efficiency and poor precision of traditional APM (automated people mover system), it is necessary to study the APM technology for track misalignment detection. Method The l...

Disturbance Deformation Influence and Field Measurement Study of Metro Shield Under-passing High Building Foundation

Objective With an increasing number of cases involving metro shield tunneling through or in proximity to high buildings in urban rail transit projects, the shield tunneling method inevitably causes disturbances to the gr...

Pantograph Lifting Collision Characteristics under Complex Working Conditions

[Objective] To investigate the dynamics issues arising from the frequent lifting and lowering of pantographs in multi-mode hybrid traction trains, the pantograph collision characteristics are analyzed. [Method] Takin...

Download PDF file
  • EP ID EP744342
  • DOI 10.16037/j.1007-869x.2024.09.034
  • Views 46
  • Downloads 0

How To Cite

Jiawei ZHAO, Li WANG, Dayun ZOU, Genjun CHEN, Kai XIE (2024). Research on Reactive Power Coordination Control Scheme of Energy Feedback Device in Urban Rail Transit Power Supply System. Urban Mass Transit, 27(9), -. https://europub.co.uk/articles/-A-744342