RESIZABLE SCANNING RASTER GENERATION IN TELEVISION OPTICAL MICROSCOPE

Abstract

High resolution cathode-ray tube (CRT) uses in television optical microscope (TOM) for lighting of investigated microobject (MO) [1–4]. Light, which goes through investigated MO, or reflected from it, projects on photosensitive target of photoelectron multiplier (PEM). On the output of PEM is generated electrical signal. Amplitude of this signal corresponds to the light, which coming from investigated MO. This signal is used to display researched MO image on television screen or personal computer screen. Resolution of CRT allows to generate scanning raster, which can has more then 4000×4000 elements of the image. Resolution of television screen is much lower (usually, doesn’t exceed 550×720 image formation elements). This feature of TOM allows to reduce size of scanning raster. In this way, is the possibility to get enlarged image of investigated MO or his part without loss of resolution. For getting enlarged image of selected part of researched MO is used offset of reduced scanning raster. For expansion of functionality, TOM generates scanning raster in television standard and in small-frame mode. Using of personal computer allows to form scanning raster by analog or digital-analog way. Independent offset of reduced raster requires special circuit solutions. One of these solutions is using of voltage-to-current converter VCC for precision current formation in load. The block diagram is developed for sweep signal generation unit by one coordinate. Composition of block diagram includes control unit of operation modes, generator of sawtooth voltage signal, generator of offset signal, memory unit, digital-to-analog converter of signal, commutator, regulator of sweep signal amplitude, amplifier-limiter of scanning ray deviation signal. The block diagram of sweep signal generation unit for another coordinate is the same. Main requirements of magnetic deflection system is defined. Shown, that main design parameters of magnetic deflection system, which influence on parameters of TOM is inductance of deflection coils, own resonance frequency, active resistance, maximum current, that is needed for deflection of light scanning ray to the outer point of raster.50 Been analyzed requirements for voltage-to-current converter, which should provide strong precision of input signals to current in load converting, stability of current value, and high performance. They execute by scheme of direct current amplifier using direct current amplifier with deep negative feedback by current. Signal of negative feedback is formed on precision resistance, which is switched consistently with inductive load. All of the above requirements should be performed with minimal intake power. Shown charts of parameters of voltage-to-current converter from design parameters which using in deflection coils of magnetic deflection system. Been defined minimum supply voltage of voltage-to-current converter, which is used for magnetic deflection system power with different design parameters. Also, shown, that using deflection coils with small inductivity needs less voltages of power supply, but leads to an increase of average power consumption. Defined main dynamic parameters of voltage-tocurrent converter using magnetic deflection system with different design parameters for scanning raster formation.

Authors and Affiliations

Volodymyr Shkliarskyy, V. Goy, Rostyslav Matviyiv, Yuriy Matiieshyn

Keywords

Related Articles

VERTICAL HANDOVER ACCESS SELECTION IN MOBILE SDR SYSTEM

In order to satisfy emerging user requirements in advanced services/applications, provided seamlessly, operators have to deploy complex network topologies of heterogeneous nature, where different Radio Access Technologie...

ALGORITHMIC SOFTWARE OF A TELEVISION SCANNING OPTICAL MICROSCOPE WORK IN THE STUDY OF DYNAMIC MICROOBJECTS

The questions concerning algorithmic software of the work of a television scanning optical microscope (TSOM) during research and determination of various parameters and characteristics of single and group dynamic microob...

DETERMINATION OF ENERGY EFFICIENCY ACOUSTIC DEVICES IN THE OPTICAL TRANSPORT NETWORK USING 3D-ANALYSIS OF ELECTROMECHANICAL COUPLING

In this paper we investigate electromechanical coupling coefficient. We show the investigation importance of spatial distribution coefficient of electromechanical coupling. This parameter characterizes the energy efficie...

DEVELOPING OF MOBILE ROBOTIC TECHNICAL SYSTEM BASED ON FPGA

In the article the structure of the designed FPGA based mobile robot technical system is described. For the design the block-hierarchical approach was used. This system includes the following elements: - the MicroBlaze s...

DYNAMICS OF PULSE SIGNAL FORMING FROM DISTAL ZONES OF RADIAL ARTERIES

In last time new methods and hardware-software system, which combine eastern medicine traditions and western technologies are commonly used in diagnostic practice. Pulse diagnostics is one of the ancient methods for dise...

Download PDF file
  • EP ID EP457178
  • DOI -
  • Views 114
  • Downloads 0

How To Cite

Volodymyr Shkliarskyy, V. Goy, Rostyslav Matviyiv, Yuriy Matiieshyn (2016). RESIZABLE SCANNING RASTER GENERATION IN TELEVISION OPTICAL MICROSCOPE. Вісник Національного університету "Львівська політехніка", серія "Радіоелектроніка та телекомунікації", 849(2016), 49-56. https://europub.co.uk/articles/-A-457178