Abstract

In this paper I presented the role of filters duplex in structure of voice repetors, operating principles specific subassembly transmission and subassembly reception. I wanted to do a filter, for building a repeater duplexer for band 144Mhz - 146Mhz. I described how to make a cavity. Leaving the wiring diagram and I checked, depending on the size, if designed cavity can be used for VHF frequencies corresponding. I examined the response of this filter, for receiving and transmitting frequencies, specific to repetor that will be made.

Authors and Affiliations

Gheorghe SAUCIUC

Keywords

Related Articles

Comparative Analysis Of Three Versions Of A Capacitor-Less LDO Structure That Supplies A Rail-To-Rail VCO

This paper presents three circuit implementations of a low-dropout voltage regulator (LDO) structure that supplies a rail-to-rail voltage controlled oscillator (VCO) operating at 2.5GHz. The LDOs comprise only a small de...

Digital Implementation of The Sigmoid Function for FPGA Circuits

In this paper, is proposed a method to implement in FPGA (Field Programmable Gate Array) circuits different approximation of the sigmoid function. Three previously published piecewise linear and one piecewise second-orde...

Fuzzy Logic Based Decision Making for Hydroelectric Energy Generation in a Cascaded Hydropowerplants

Hydroelectric energy is a major source of renewable electricity in the world. The industry is continuously searching for ways to improve the efficiency and reliability with which it produces energy. A method based on sub...

Divide-and-Conquer Piecewise Linear Approximation of Gain and Phase Evaluation

Certain approaches to phase approximation ask as a first step in implementation for a piecewise linear fitting of gain. When the breakpoints are given, there are few ways to determine the slopes of the broken line approx...

Neuro-Fuzzy stereo camera calibration architectures used in interactions with medical volumes

Computer assisted diagnosis/surgery systems need improved solutions for visualization and interactions, as the virtual probe tools. This work presents such an interaction tool and its applications in medical imaging. The...

Download PDF file
  • EP ID EP130406
  • DOI -
  • Views 146
  • Downloads 0

How To Cite

Gheorghe SAUCIUC (2012). Resonant Cavities for Duplex Filters in VHF Repeaters: Analysis, Implementation, and Testing. Acta Technica Napocensis- Electronica-Telecomunicatii (Electronics and Telecommunications), 53(3), 25-29. https://europub.co.uk/articles/-A-130406