RESONANT SOURCE FOR THE SUPPLY OF ELECTRIC FIELD PROBE CALIBRATION SYSTEM AT FREQUENCIES BETWEEN 50Hz AND 50KHz
Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2010, Vol 34, Issue 34
Abstract
Electromagnetic environmental conditions checking and provision regarding long and short time human personal and occupational exposure is regulated by international standards. Generally, the human being is exposed mainly to the field generated by the 50 Hz low, medium and high voltage equipments or transmission lines of the electric power system but in industrial applications also higher frequencies are used in certain technological processes. This low and medium frequency electric fields have values in the range 0.5V/m − 100kV/m for frequencies within 5Hz and 400kHz. Modern electric field measuring devices works on one or three axes, with software for measured data acquisition & storage and sometimes with the possibility of GPS source localization. In Romania, there are no installations for the periodical calibration of the instruments for low and medium frequency electric field measurement. The calibration in accredited foreign laboratories is expensive and the said instruments are used almost exclusively based on the certificates issued by supplier at purchasing. The paper presents an innovative calibration solution based on a double resonant source which enables field strengths up to 100 kV/m to be achieved in a wide frequency range within 50Hz and 50kHz.
Authors and Affiliations
Andrei MARINESCU
Harmonics Analysis Using DFT
Harmonics analysis is established by international standards as well as national norms [6], [7]. There are also definitions and calculus relationships for the indicators considered representative for this non quality...
LOW POWER GENERATING SYSTEM, SIMULATION AND ANALYSIS
Most distributed generating systems (DG) are not new in a technological respect, they are receiving increased attention today because of their ability to provide backup power, improved power quality, and ancillary servic...
Control of Flow and Pressure in the Cooling Water Circuit of a Thermal Power Plant Using Fuzzy Logic
Optimum operation of cooling water systems means minimum use of water while maintaining proper temperatures to limit algae growth and cool all equipment properly. Combined, the application of inverters and cooling water...
Evaluating RMS of Linearly Variable Magnitude Waveforms by Using FFT and WPT. Theory and Practice
The paper deals with the evaluation of the Root Mean Square (RMS) indices of signals with linearly variable magnitude by using Wavelet Packet Transform (WPT) and Fast Fourier Transform (FFT). Firstly there is presented a...
A DISO NEURO-FUZZY CONTROL FOR DC SERVODRIVES
The paper follows a previous work that made the synthesis of a neuro-fuzzy controller with double input and single output for positioning systems with DC motors. Now, the new system is put into operation using models and...