RESONANT SOURCE FOR THE SUPPLY OF ELECTRIC FIELD PROBE CALIBRATION SYSTEM AT FREQUENCIES BETWEEN 50Hz AND 50KHz

Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2010, Vol 34, Issue 34

Abstract

Electromagnetic environmental conditions checking and provision regarding long and short time human personal and occupational exposure is regulated by international standards. Generally, the human being is exposed mainly to the field generated by the 50 Hz low, medium and high voltage equipments or transmission lines of the electric power system but in industrial applications also higher frequencies are used in certain technological processes. This low and medium frequency electric fields have values in the range 0.5V/m − 100kV/m for frequencies within 5Hz and 400kHz. Modern electric field measuring devices works on one or three axes, with software for measured data acquisition & storage and sometimes with the possibility of GPS source localization. In Romania, there are no installations for the periodical calibration of the instruments for low and medium frequency electric field measurement. The calibration in accredited foreign laboratories is expensive and the said instruments are used almost exclusively based on the certificates issued by supplier at purchasing. The paper presents an innovative calibration solution based on a double resonant source which enables field strengths up to 100 kV/m to be achieved in a wide frequency range within 50Hz and 50kHz.

Authors and Affiliations

Andrei MARINESCU

Keywords

Related Articles

Modern AC Drive System with Induction Machine

The induction machine is widespread in AC drive system. The energy efficiency of the induction machine during dynamic regimes is up to 40%. Therefore, for the electrical drives with frequent dynamics (starting, breaki...

The Load Influence on the Diagnosis of the Three-Phase Rectifier by Using the Analytical Model Method

For the operation of the static power converters, the experience of an expert is absolutely necessary for competitive operation. Minor faults or defects of the elements of the static power converters can lead to ravag...

Using a Shape Memory Alloy Spring Actuator to Increase the Performance of Solar Tracking System

The exclusive properties (e.g. one way and two way shape memory effect, superelasticity, etc.) exhibited by shape memory alloys (SMAs) offer the possibility of producing smart sun tracking mechanisms for photovoltaic...

Technical Aspects Regarding Electromagnetic Compatibility Compliance of the Electric and Electronic Integrated Systems

The modern world’s needs of electric and electronic devices and systems lead to a continuously electromagnetic interferences growing in ways that were hard to predict few decades ago, a serious reason to consider the ele...

USING A LABVIEW AND FIELD POINT I/O MODULE FOR CATALYTIC ISOTOPIC EXCHANGE COLUMN CONTROL AND OPERATORS TRAINING

This paper presents the main advantages of using the programmable automation controller (PAC) and LabVIEW software in the operation of an isotopic exchange column which is part of ETRF (experimental tritium removal facil...