RESONANT SOURCE FOR THE SUPPLY OF ELECTRIC FIELD PROBE CALIBRATION SYSTEM AT FREQUENCIES BETWEEN 50Hz AND 50KHz

Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2010, Vol 34, Issue 34

Abstract

Electromagnetic environmental conditions checking and provision regarding long and short time human personal and occupational exposure is regulated by international standards. Generally, the human being is exposed mainly to the field generated by the 50 Hz low, medium and high voltage equipments or transmission lines of the electric power system but in industrial applications also higher frequencies are used in certain technological processes. This low and medium frequency electric fields have values in the range 0.5V/m − 100kV/m for frequencies within 5Hz and 400kHz. Modern electric field measuring devices works on one or three axes, with software for measured data acquisition & storage and sometimes with the possibility of GPS source localization. In Romania, there are no installations for the periodical calibration of the instruments for low and medium frequency electric field measurement. The calibration in accredited foreign laboratories is expensive and the said instruments are used almost exclusively based on the certificates issued by supplier at purchasing. The paper presents an innovative calibration solution based on a double resonant source which enables field strengths up to 100 kV/m to be achieved in a wide frequency range within 50Hz and 50kHz.

Authors and Affiliations

Andrei MARINESCU

Keywords

Related Articles

Concerning the Monitoring of the Electric Contacts Electroerosion of the Circuit Breakers from Medium Voltage Stations of CEZ Craiova

The monitoring and diagnosis of electrical equipment aims to increase the lifetime of the electrical equipment from the substations for medium and high voltage. This is one of the main concerns of the users of the high v...

MICRO-HYDROPOWER STATION FOR KINETIC ENERGY CONVERSION OF FLOWING WHATER

An efficient conversion of kinetic energy of river water into mechanical or electrical energy without building barrages is provided by micro-hydropower stations. Increased efficiency is achieved by an optimum position of...

Design Optimization of an Asynchronous Motor Used in Light Railway Traction

The appropriateness of this work is provided by highlighting some aspects insufficiently treated in the areas of designing and dimensioning of asynchronous traction motors associated with light traction static converters...

STUDY OF THE DC VOLTAGE CIRCUIT BREAKERS COMMUTATION WITH EMTPWORKS SOFTWARE SIMULATIONS

DC voltage circuit breakers, initially intended for protecting and disconnecting the rectifiers (AC/DC converters), have a wide using in high voltage systems. This paper presents the results of turn-off LC circuit simula...

TIME-DOMAIN BASED ACTIVE COMPENSATION STRATEGIES UNDER NONSINUSOIDAL CONDITIONS IN THREE-PHASE THREE-WIRE SYSTEMS

This paper deals with the peculiarities involved by the operation under nonsinusoidal voltage conditions on the generation of the reference compensating current in three-phase three-wire shunt active power filters. The t...

Download PDF file
  • EP ID EP118943
  • DOI -
  • Views 109
  • Downloads 0

How To Cite

Andrei MARINESCU (2010). RESONANT SOURCE FOR THE SUPPLY OF ELECTRIC FIELD PROBE CALIBRATION SYSTEM AT FREQUENCIES BETWEEN 50Hz AND 50KHz. ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica, 34(34), 39-43. https://europub.co.uk/articles/-A-118943