RESONANT SOURCE FOR THE SUPPLY OF ELECTRIC FIELD PROBE CALIBRATION SYSTEM AT FREQUENCIES BETWEEN 50Hz AND 50KHz

Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2010, Vol 34, Issue 34

Abstract

Electromagnetic environmental conditions checking and provision regarding long and short time human personal and occupational exposure is regulated by international standards. Generally, the human being is exposed mainly to the field generated by the 50 Hz low, medium and high voltage equipments or transmission lines of the electric power system but in industrial applications also higher frequencies are used in certain technological processes. This low and medium frequency electric fields have values in the range 0.5V/m − 100kV/m for frequencies within 5Hz and 400kHz. Modern electric field measuring devices works on one or three axes, with software for measured data acquisition & storage and sometimes with the possibility of GPS source localization. In Romania, there are no installations for the periodical calibration of the instruments for low and medium frequency electric field measurement. The calibration in accredited foreign laboratories is expensive and the said instruments are used almost exclusively based on the certificates issued by supplier at purchasing. The paper presents an innovative calibration solution based on a double resonant source which enables field strengths up to 100 kV/m to be achieved in a wide frequency range within 50Hz and 50kHz.

Authors and Affiliations

Andrei MARINESCU

Keywords

Related Articles

A MODIFIED PETRI NET FRAMEWORK FOR HYBRID SYSTEM MODELING

In order to achieve the framework for analysis of hybrid dynamic systems, different approaches of modeling are used and at present is already an abundance of such paradigms, including Petri Nets. Often, the continuous dy...

Small Scale Model of Automatic Barrier Powered by Photovoltaic Panel

Access control systems offer numerous benefits and are able to constitute extremely good solutions for securing an area of high or very high importance. An access control system allows restriction, monitoring and directi...

Study of the Reactive Power Side Effects for Tariff and Compensation Purpose at the Transmission Networks’Users

The reactive power flows affect voltages, losses and transmission capacities. Thus MVAR flows are a matter of increasing concern for the grid operators and the Romanian Regulatory Authority for Energy has established the...

Design and Performance of the Voltage Control Loop in Induction Heating Systems with L-LC Resonant Inverters

In the induction heating systems1 with voltage source inverter and resonant L-LC load, different ways to control the power transferred to the heated piece are possible. This paper takes into consideration separate contro...

COMPUTATIONAL ANALYSIS OF HYDRODYNAMIC EFFECTS IN HYDRAULIC FLOW TURBINES (PART 1)

Research and elaboration of the systems for conversion of renewable energy sources (RSE) as a research objective present great interest and importance. Hydraulic energy currently is one of the most used, cheap and clean...

Download PDF file
  • EP ID EP118943
  • DOI -
  • Views 98
  • Downloads 0

How To Cite

Andrei MARINESCU (2010). RESONANT SOURCE FOR THE SUPPLY OF ELECTRIC FIELD PROBE CALIBRATION SYSTEM AT FREQUENCIES BETWEEN 50Hz AND 50KHz. ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica, 34(34), 39-43. https://europub.co.uk/articles/-A-118943