Response to Neutrons and γ-rays of Two Liquid Scintillators

Abstract

UltimaGoldTM AB and OptiphaseTrisafe are two liquid scintillators made by Perkin Elmer and EG & G Company respectively. Both are commercially promoted as scintillation detectors for α and β particles. In this work, the responses to γ-rays and neutrons of UltimaGoldTM AB and OptiphaseTriSafe liquid scintillators, without and with reflector, have been measured aiming to use these scintillators as γ-rays and neutron detectors. Responses to γ-rays and neutrons were measured as pulse shape spectra in a multichannel analyzer. Scintillators were exposed to gamma rays produced by 137Cs, 54Mn, 22Na and 60Co sources. The response to neutrons was obtained with a 241AmBe neutron source that was measured to 25 and 50 cm from the scintillators. The pulse height spectra due to gamma rays are shifted to larger channels as the photon energy increases and these responses are different from the response due to neutrons. Thus, UltimaGoldTM AB and OptiphaseTrisafe can be used to detect γ-rays and neutrons.

Authors and Affiliations

Hector Rene Vega-Carrillo , Martha Isabel Escalona-Llaguno , Luis Hernandez-Adame , Sergio M. Sarmiento-Rosales , Claudia A. Márquez-Mata , Guillermo E. Campillo-Rivera , V. P. Singh , Teodoro Rivera-Montalvo , Segundo Agustin Martínez-Ovalle

Keywords

Related Articles

A Scaling Law for L-Shell X-Ray Production Cross Sections Induced by Impact of 4He+, 9Be2+, and 14N2+ Ions

Experimental results of L-subshell X-ray production cross sections induced by the impact of several ions heavier than protons were compiled in order to propose possible scaling laws. The ions of interest in this work are...

Formation of Medium-Heavy Elements in Rapid Neutron Capture Process

We predict the neutron drip-line and simulate the r—process path for Cu — Sn, based on the calculation of binding energy in the frame-work of relativistic and non-relativistic mean field formalisms. We also compare the q...

Radiation Induced Oxidation Reactions of Ferrous Ions: An Agent-based Model

Chemical Fricke dosimeter in the laboratory can be submitted to gamma radiation at low temperatures to study the evolution of oxidation reactions induced by radiation, a key process to understand the formation of complex...

Alpha Emitter Intrinsic Concentration in Copper required for Nuclear Spectrometry Application

Low-level radioactivity content in copper are employed for bolometric thermal radiation sensors and astro-nuclear spectrometers. The required lowest achievable alpha emitters concentration, for treated and untreated surf...

Characterization of LR-115 Type 2 Detectors for Monitoring Indoor Radon 222: Determination of the Calibration Factor

The city of Lima, capital of Peru, has about 11 million inhabitants. Lima has no records about the indoor Radon 222 concentration levels in dwellings. Hereby, we are planning to register the indoor radon concentrations i...

Download PDF file
  • EP ID EP566986
  • DOI 10.15415/jnp.2019.6.02.161-169
  • Views 322
  • Downloads 0

How To Cite

Hector Rene Vega-Carrillo, Martha Isabel Escalona-Llaguno, Luis Hernandez-Adame, Sergio M. Sarmiento-Rosales, Claudia A. Márquez-Mata, Guillermo E. Campillo-Rivera, V. P. Singh, Teodoro Rivera-Montalvo, Segundo Agustin Martínez-Ovalle (2019). Response to Neutrons and γ-rays of Two Liquid Scintillators. Journal of Nuclear Physics, Material Sciences, Radiation and Applications, 6(2), 161-169. https://europub.co.uk/articles/-A-566986