Response to Neutrons and γ-rays of Two Liquid Scintillators

Abstract

UltimaGoldTM AB and OptiphaseTrisafe are two liquid scintillators made by Perkin Elmer and EG & G Company respectively. Both are commercially promoted as scintillation detectors for α and β particles. In this work, the responses to γ-rays and neutrons of UltimaGoldTM AB and OptiphaseTriSafe liquid scintillators, without and with reflector, have been measured aiming to use these scintillators as γ-rays and neutron detectors. Responses to γ-rays and neutrons were measured as pulse shape spectra in a multichannel analyzer. Scintillators were exposed to gamma rays produced by 137Cs, 54Mn, 22Na and 60Co sources. The response to neutrons was obtained with a 241AmBe neutron source that was measured to 25 and 50 cm from the scintillators. The pulse height spectra due to gamma rays are shifted to larger channels as the photon energy increases and these responses are different from the response due to neutrons. Thus, UltimaGoldTM AB and OptiphaseTrisafe can be used to detect γ-rays and neutrons.

Authors and Affiliations

Hector Rene Vega-Carrillo , Martha Isabel Escalona-Llaguno , Luis Hernandez-Adame , Sergio M. Sarmiento-Rosales , Claudia A. Márquez-Mata , Guillermo E. Campillo-Rivera , V. P. Singh , Teodoro Rivera-Montalvo , Segundo Agustin Martínez-Ovalle

Keywords

Related Articles

Shape Coexistence in Hot Rotating 100Nb

Temperature and angular momentum induced shape changes in the well deformed 100Nb have been investigated within the theoretical framework of Statistical theory combined with triaxially deformed Nilson potential and Strut...

Improvements to the X-ray Spectrometer at the Aerosol Laboratory, Instituto de Física, UNAM

Due to the demands of better (accurate and precise) analytical results using X-ray Fluorescence (XRF) at the Aerosol Laboratory, Instituto de Física, UNAM, it was necessary to carry out improvements in instrumentation an...

Application of a CdTe Detector for Measurements of Mammographic X-ray Spectra

This work aims to characterize mammographic x-ray beams incident and transmitted by breast phantoms (from 0 to 45 mm) composed from known proportion of glandular and adipose tissue-equivalent materials. This study was pe...

Xps Study of the Oxidation State of Uranium Dioxide

In this article we report an investigation of the oxidation state of uranium dioxide using X-Ray Photoelectron Spectroscopy, and by comparing to results obtained in previous studies. We find that uranium dioxide in powde...

Mini Subcritical Nuclear Reactor

A mini subcritical nuclear reactor was designed using Monte Carlo methods. The reactor has light water as moderator, natural uranium as fuel, and a 239PuBe neutron source. In the design uranium fuel was modeled in an arr...

Download PDF file
  • EP ID EP566986
  • DOI 10.15415/jnp.2019.6.02.161-169
  • Views 331
  • Downloads 0

How To Cite

Hector Rene Vega-Carrillo, Martha Isabel Escalona-Llaguno, Luis Hernandez-Adame, Sergio M. Sarmiento-Rosales, Claudia A. Márquez-Mata, Guillermo E. Campillo-Rivera, V. P. Singh, Teodoro Rivera-Montalvo, Segundo Agustin Martínez-Ovalle (2019). Response to Neutrons and γ-rays of Two Liquid Scintillators. Journal of Nuclear Physics, Material Sciences, Radiation and Applications, 6(2), 161-169. https://europub.co.uk/articles/-A-566986