Retest improvement for minipool nucleic acid testing positive samples

Journal Title: Chinese Journal of Blood Transfusion - Year 2024, Vol 37, Issue 2

Abstract

Objective To analyze the correlation between the distribution interval of minipool nucleic acid testing(NAT) positive CT value and the resolution rate, so as to improve the retest model and reduce residual risk of blood transfusion. Methods The resolution testing results by Cobas S201 system of our blood center from January 2017 to December 2021 were retrospective analyzed, and the retest model was developed based on the distribution interval of CT values. For minipool NAT HBV positive samples from March 2022 to March 2023, synchronous detection was conducted by Cobas S201 and Panther detection system, and the detection results were statistically analyzed. Results From 2017 to 2021, 474 were minipool NAT positive, among which 324 were HBV positive, accounting for 68.35%. From 2017 to 2020, the proportion of HBV positive per year was significantly higher than that of HCV and HIV(P<0.05). In resolution testing, 167 were HBV repeatable positive and 157 were HBV non-repeatable positive, accounting for 51.54% and 48.46% of HBV minipool NAT positive. HBV repeatable positive samples were with three intervals: CT value≤36, 36<CT value≤40 and CT value>40, with the resolution rate at 95.8%, 56.5% and 14.8% respectively(P<0.05). The proportion of 36<CT value≤40 interval in resolution positive group and resolution negative group was 80.8% and 66.2% respectively, and showed statistical differences compared with other two intervals(P<0.05). From March 2022 to March 2023, 65 were HBV positive in minipool NAT, with 5, 12, and 48 in CT value ≤36, CT value >40, 36<CT value≤40 intervals respectively, with the concordance rate at 100%, 100%, and 81.25% by Cobas S201 and Panther detcetion. Nine samples presented inconsistent results: 4 samples were resolution negative by Cobas S201 but positve by Panther, 3 were repeatable positive and 1 was non-repeatable positive by Cobas S201. These 9 samples were seen as unqualified, but according to original rules(non-repeatable positive samples were seen as qualified), missed detection of at least 3 samples might occur. Conclusion There was a certain proportion of non-repeatable positive samples in positive pool, and the rules (non-repeatable positive samples were seen as qualified) have a risk of missed detection. Those with 36<CT value ≤40 interval should be rested to ensure blood safety and save restest cost.

Authors and Affiliations

Yun HOU, Qiuxia FENG, Bei LI, Longmu ZHANG, Zhongsi YANG, Shuxian JIAO

Keywords

Related Articles

Molecular genetic analysis of a patient with double population of red blood cells for RhD antigen

Objective To solve the difficulty of RhD blood group typing in a patient with double population(DP) of red blood cells for RhD antigen by serological and genotyping analysis. Methods Separation of the two populations of...

Application of inspection sheet in apheresis platelet collection

Objective To explore the effect of inspection sheet on improving the quality of apheresis platelet, the satisfaction of blood donors and the cooperation ability of phlebotomists in the process of apheresis platelet colle...

Effect of red blood cell preservation solution on serum agglutination reaction of specific patients

Objective To explore the precautions of pre-transfusion examination in patients with antibodies to erythrocyte protective solution, discrepant ABO blood typing results, and positive unexpected antibodies, so as to ensure...

Chimeric antigen receptor T-associated cytokines release syndrome managed by therapeutic plasma exchange and tumor necrosis factor inhibitors: a case report

Objective To learn more about the role of therapeutic plasma exchange in the management of cytokines release syndrome(CRS) after chimeric antigen receptor T(CAR-T) infusion by reviewing and analyzing the diagnosis and tr...

Preliminary discussion on the causes and influencing factors of blood discarding

Objective To conduct a retrospective statistical analysis of the blood discarding situation in Xuzhou Central Blood Station in the past 5 years, so as to explore relevant measures and strategies to reduce blood discardin...

Download PDF file
  • EP ID EP738765
  • DOI 10.13303/j.cjbt.issn.1004­549x.2024.02.011
  • Views 3
  • Downloads 0

How To Cite

Yun HOU, Qiuxia FENG, Bei LI, Longmu ZHANG, Zhongsi YANG, Shuxian JIAO (2024). Retest improvement for minipool nucleic acid testing positive samples. Chinese Journal of Blood Transfusion, 37(2), -. https://europub.co.uk/articles/-A-738765