Role of D-Mannose as an Antiglycolytic Agent to Eliminate Preanalytical Error in Glucose Testing
Journal Title: Journal of Clinical and Diagnostic Research - Year 2018, Vol 12, Issue 7
Abstract
Introduction: Correct assessment of glucose is required for diagnosis of diabetes and monitoring of antihyperglycaemic therapy in adults as well monitoring neonatal hypoglycaemia. As per American Diabetes Association, sodium fluoride alone is an unreliable antiglycolytic agent in vitro due its ineffective action during first 4 hours of sample collection. Aim: To evaluate the efficacy of mannose as compared to conventional antiglycolytic agent for blood glucose estimation and to assess its use as a preservative for other routine biochemical analytes. Materials and Methods: The study was carried out in three steps. Fifteen samples of plasma were aliquoted into 5 parts. One was without any additive and in other four D-mannose was added in concentration of 1,2,3 and 5 mg/mL. Blood glucose was analysed immediately, at 1.5 hours, 3 hours and 5 hours to optimize the concentration of D-mannose. Fifteen serum samples were aliquoted into 2 parts, one without any additive and the other with D-mannose at a concentration of 3 mg/dL. Both were subjected for routine biochemistry to check for any interference by D-mannose in analysis. Fifteen samples were collected in heparin (with mannose added in concentration of 3mg/dL), plain tube, EDTA and sodium fluoride vacutainers. Blood glucose and other routine analytes were measured immediately, at 1.5 hrs and 3 hrs to compare D-mannose with other preservatives. Results were analysed using Student’s t-test. Results: Optimal concentration of D-mannose was found to be of 3 mg/mL. D-Mannose showed a less decrease of blood glucose at the end of 3 hrs compared to sodium fluoride. D-Mannose does not interfere with estimation of any analytes except potassium. Creatine kinase was found to be lower with EDTA compared to other preservatives. Conclusion: D-Mannose is an ideal preservative for blood glucose. All routine analytes (except potassium) can be estimated from a single vacutainer containing D-mannose at a concentration of 3 mg/dL.
Authors and Affiliations
Mithu Banerjee, Ankit Batra, Pratibha Misra
Comparison of Accuracy of Bracket Placement by Direct and Indirect Bonding Techniques using Digital Processing - An In-Vitro Study
ABSTRACT Introduction: Accuracy of bracket positioning is an essential part of successful orthodontic treatment. Ideally placed brackets help in treatment mechanics and improve consistency of the result. The current stud...
Vocal Hoarseness in Rheumatoid Arthritis: Early Recognition is Critical
Images in Medicine
Effect of Intracuff Inflation with Alkalinised Lignocaine, Saline and Air on Early Postoperative Airway Morbidity-A Randomised Control Trial
ABSTRACT Introduction: Endotracheal intubation is the gold standard of airway management, and usage of the cuffed Endotracheal Tube (ETT) is routine clinical practice. The ETT provides adequate ventilation and reduces as...
Estimation of Total Time Duration and Comfort Equation of Three Different Appliances used to Manage the Condition of Single Tooth Developing Anterior Crossbite in Children
ABSTRACT Introduction: Single tooth anterior dental crossbite is a major aesthetic and functional concern to the parents during the early stages of dental development with evident incidence rate during the early mixed de...
Perception of Community Pharmacy Personnel towards Patient Counseling and Continuing Pharmacy Education Programs in Aden, Yemen
Introduction: Patient counseling is a major component of pharmaceutical care, especially in community pharmacy settings. However, most community pharmacists still do not offer patient-oriented services. Despite the benef...