Rotation of breast prostheses and quality of life of patients after augmentation mammoplasty

Journal Title: Серце і судини - Year 2018, Vol 0, Issue 2

Abstract

The aim — to evaluate the quality of life (QL) of patients after the primary submuscular augmentative mammoplasty (SAM) during one year depending on the presence and degree of rotation of the mammary prosthesis (RMP). Materials and methods. The work was carried out in the Department of Surgery No. 4. The study included 170 women whose QL was evaluated before and one year after SAM using the international questionnaire MOS­SF­36. Patients were divided into two groups: comparison group — 94 women who underwent SAM performed by traditional method, basic group — 76 women who underwent SAM performed by technique for strengthening of the upper pole of submuscular neopouch. The reference values of QL were obtained from 30 women. Patients in the study group were not statistically different in age, body mass index (BMI), weight of prostheses, percentage of pregnant and breastfeeding patients. The final point of the study was QL one year after the SAM by the international questionnaire MOS­SF­36; the intermediate point of the study was the frequency of RMP one year after the SAM. Results and discussion. Indexes of QL before the operation in women of both groups did not differ statistically and were close to the reference values. One year after the SAM 143 (76.1 %) prostheses rotated in the comparison group, 46 (30.3 %) — in the main group (p = 0.001). There were also differences in the degree of RMP (p = 0.001) due to the absence of clinically significant RMP in the main group (90° or more) compared with 13 (13.8 %) cases of RMP in the comparison group (p = 0.001). A year after the operation in the study groups, an increase in the mean values of all indicators of QL was noted. Indicators of QL in main group were significantly better than in the comparison group, except for the indicator of physical functioning. Differences between the groups were caused by the presence in the comparison group of women with clinically significant RMP. Thus, in women with clinically significant RMP, all of the QL values were significantly lower than in women without clinically significant RMP (all p < 0.01). Conclusions. Clinically significant RMP considerably impairs the patients’ QL one year after the SAM. Such patients have significantly lower psychic and physical health components compared to patients without RMP. SAM in the remote period provides improvement of patients’ QL in case of the absence of clinically significant RMP. The developed method of RMP prophylaxis after SAM is associated with significantly better indicators of QL compared to the classical technique according to all scales of the mental component of health and two scales of the physical component of health.

Authors and Affiliations

V.  G. Mishalov, O.  I. Zakhartseva, V.  V. Khrapach, L.  Yu. Markulan

Keywords

Related Articles

Actual methods of carotid body tumor diagnosis

The aim — to improve the carotid body tumors (CBT) diagnosis. Materials and methods. The article presents with the analysis of the structure and the results of the diagnosis and surgical treatment of 65 patients who were...

Comparison of clinical characteristics of patients with chronic heart failure and reduced left ventricular ejection fraction in regard of state of cognitive function

The aim — to establish clinical factors associated with cognitive dysfunction (CD) in patients with chronic heart failure (CHF) and reduced left ventricular ejection fraction (LV EF). Materials and methods. We examined...

Infrequent causes of thrombophilia

In patients with thyroid dysfunction, various violations of coagulation and fibrinolysis can be observed: from subclinical, with only laboratory changes, to clinically significant thrombosis or fatal hemorrhages. The sta...

Experience in treatment of post-traumatic arteriovenous discharges syndrome resulting from gunshot wounds of the main vessels

The aim — to analyze the experience of surgical treatment of patients with posttraumatic arteriovenous discharges in the lower limbs. During the period of the Anti-Terrorist Operation in the east of Ukraine, 8 patients w...

Long-term results of complex therapy in patients with nonreconstructible chronic lower limb ischemia

The aim — to improve the results of surgical treatment of patients with chronic critical lower limb ischemia by developing methods of autologous transplantation of multipotent stem mesenchymal stromal cells, administrati...

Download PDF file
  • EP ID EP332333
  • DOI 10.30978/HV2018254
  • Views 92
  • Downloads 0

How To Cite

V.  G. Mishalov, O.  I. Zakhartseva, V.  V. Khrapach, L.  Yu. Markulan (2018). Rotation of breast prostheses and quality of life of patients after augmentation mammoplasty. Серце і судини, 0(2), 54-59. https://europub.co.uk/articles/-A-332333