Abstract

Commencing with incandescent light bulb, every load today creates harmonics. Unfortunately, these loads vary with respect to their amount of harmonic content and response to problems caused by harmonics. Issue of Harmonics are of a greater concern to engineers, building designers and in industrial applications because they do more than distort voltage waveforms, they can overheat the building wiring, cause nuisance tripping, overheat transformer units, and cause random end-user equipment failures. Thus power quality has become more and more serious with each passing day. As a result active power filter (APF) gains much more attention due to excellent harmonic compensation. But still the performance of the active filter seems to be in contradictions with different control techniques. The main objective of this paper is to analyse shunt active filter with fuzzy and pi controllers. To carry out the analysis, we consider active and reactive power method (p-q). Extensive simulations were carried out; simulations were performed with balance, unbalanced and non sinusoidal conditions. Simulation results validate the dynamic behaviour of fuzzy logic controller over pi controller.

Authors and Affiliations

S. Mikkili, A. K. Panda

Keywords

Related Articles

Performance Analysis of Non-Isolated DC-DC Buck Converter Using Resonant Approach

DC-DC converters preserve or control the output DC voltage. Due to parasitic constituents such as leakage capacitance of both diode and inductor, and transformer leakage inductance, DC-DC converters mostly operate on rig...

BlindSense: An Accessibility-inclusive Universal User Interface for Blind People

A large number of blind people use smartphone-based assistive technology to perform their common activities. In order to provide a better user experience the existing user interface paradigm needs to be revisited. A new...

A Comparison Among Different Parameters for the Design of a Photovoltaic/Thermal System Using Computational Fluid Dynamics

The purpose of this paper is to compare several fins, duct height, and velocity magnitudes to acquire a PhotoVoltaic/Thermal system designed through Computational Fluid Dynamics. Simulation of different fins (rectangular...

Realization of a Single-Phase Multilevel Inverter for Grid-Connected Photovoltaic System

This paper introduces the implementation of a single-phase multilevel inverter for a grid-connected photovoltaic system. The considered topology contains a full bridge converter tied to an auxiliary circuit made of two p...

Effect of River Indus Sand on Concrete Tensile Strength

In the development of Pakistan construction industry, the utilization of River Indus sand in concrete as fine aggregate has expanded tremendously. The aim of this research is to study the effect of Indus River sand on th...

Download PDF file
  • EP ID EP84800
  • DOI -
  • Views 266
  • Downloads 0

How To Cite

S. Mikkili, A. K. Panda (2011). SHAF for Mitigation of Current Harmonics Using p-q Method with PI and Fuzzy Controllers. Engineering, Technology & Applied Science Research, 1(4), -. https://europub.co.uk/articles/-A-84800