SITA STANDARD AS A SCREENING TOOL IN GLAUCOMA EVALUATION- A PROSPECTIVE STUDY TO DETERMINE ITS SPECIFICITY AND SENSITIVITY

Journal Title: Journal of Evidence Based Medicine and Healthcare - Year 2018, Vol 5, Issue 17

Abstract

BACKGROUND Characteristic visual field defects are the primary criteria to diagnose glaucoma and to monitor its progression. With the increased awareness about this disease and inclusion of glaucoma evaluation in the routine clinical examination of all patients above 40 years of age, there is a need for faster screening algorithm with good reliability, reproducibility, specificity, and sensitivity. The aim of this study was to determine the sensitivity and specificity of SITA Standard protocol and evaluate its use as a screening tool for POAG. MATERIALS AND METHODS A 1-year prospective study conducted in the Glaucoma clinic of a tertiary care hospital in Northern Karnataka, where all newly diagnosed cases underwent sequential automated perimetry with a full threshold and SITA Standard algorithm. Eye with a more severe defect was considered for analysis. RESULTS 60 eyes of 60 patients were enrolled. Mean age of presentation was found to be 63.63 years. The sensitivity of SITA Standard was found to be 95.24% while specificity was found to be 94.44%. The test time was reduced by 45.84% when compared to Full Threshold Algorithm. CONCLUSION SITA Standard reduces the test time by almost half with reliable results and thus provides a good option to be used as a screening test in glaucoma clinics.

Authors and Affiliations

Bhagyajyothi B. K, Nilesh Kumar, Niharika Niharika

Keywords

Related Articles

CONGENITAL MATURE CYSTIC TERATOMA OF PAROTID: A RARE CASE

INTRODUCTION We reported congenital mature cystic teratoma of parotid that presented as a swelling in the left parotid gland region since birth, increasing in size gradually. Teratoma is common neoplasm, but is very rare...

ANALYSIS OF SURGICAL MANAGEMENT OF A-V PATTERN DEVIATIONS

BACKGROUND A and V patterns have been commonly seen in at least one fifth of esotropia and exotropia. This study emphasizes on the efficiency of transposition along with recession/resection surgery of horizontal and obli...

NEONATAL CONJUNCTIVITIS AND ITS DRUG SENSITIVITY PATTERN

BACKGROUND Neonatal conjunctivitis is eye discharge in neonates and it is a common infection in neonates in the first month of life. Worldwide, the incidence of neonatal conjunctivitis varies from 1% to 33% depending on...

IMMUNE RECONSTITUTION INFLAMMATORY SYNDROME IN NON HIV CHILDREN ON ANTI TUBERCULAR TREATMENT: A CASE SERIES

Immune reconstitution inflammatory syndrome (IRIS) in a patient on anti-tubercular treatment (ATT) in the setting of antiretroviral therapy (ART) is well described, but it is not as common in non-HIV patients. Distinguis...

OCULAR FINDINGS OF HIV/AIDS PATIENTS AND THEIR CORRELATION WITH CD4 COUNT

BACKGROUND Ocular involvement in HIV/AIDS includes various clinical presentations including both anterior and posterior segment, most of the manifestations are those of the posterior segment. The severity of these poster...