Solar PV/Battery System Analysis for Faculty of Engineering Building, Rivers State University, Port Harcourt, Nigeria.

Abstract

The incessant power failure in the Faculty of Engineering main building, Rivers State University, Port Harcourt, Nigeria, has made the faculty and departmental offices to resort to private generators that cause air and noise pollution in an academic environment.The building, currently being occupied by the Faculty of Engineering and Faculty of Management Sciences, located on Latitude 4.50N and longitude 7.00E.This research work will proffer solution to the high running cost and its maintenance on diesel generator, it will also tackle problems caused as a result of air pollution in the Faculty.in this work a performance study of number of PV panels/arrays, battery and its analysis will be considered. The data were simulated for Solar PV system using PVSYST V5.55 Software.Inconclusion, the use of PV generator will no doubt enhance performance of the academic conditions or environment of the Staff and Students of the Faculty Engineering Main Building. We recommend that, government should encourage solar power generating system as supplement for distributed generation, Faculty of Engineering should access the abundant solar energy from the sun usingPhotovoltaic (PV) energy harnessing system to reduce the annual fuel and oil, maintenance cost, etc., on her private generating set and also put in place a Renewable Energy research centre in this school to enable student’s growth in this research area.

Authors and Affiliations

Engr. L. Dumkhana, Dr. D. C. Idoniboyeobu

Keywords

Related Articles

Wireless Energy Harvesting Using RF-Dc Module

This project presents an optimization of the Voltage doubler circuit in an energy conversion module for Radio Frequency (RF) energy harvesting system at both 900 MHz and 900Hz band. The function of the energy conversion...

Secure Logistic Management System

A good logistics management system aim and implements the active forward, and reverse flow and storage of goods, services between the point of source and the point of destination for customer's requirements. This system...

Silicon Carbide Structure Material for Optical Communication

Integration of 3-D devices, IC or MEMS, often requires a handle wafer which is removed before final packaging of the devices. This process usually uses lapping, chemical etch or high temperature heating to de-bond the ha...

The Kp - Bondage And Kp - Non Bondage Number Of Fuzzy Graphs And Graceful Graph

In this paper, we define the bondage bk(G) ,Co-bondage bkc(G), and Non- bondagebkn(G) number for any fuzzy graph and exact values for some standard graphs are found and some bounds are obtained. Moreover we also obtained...

Decimation Filter Design Optimization of ADC for ECG Processing

Digital processing of ECG for arrhythmia analysis is very much dependent upon the ECG sapling resolution. However, over sampling may increase the processing cose and under sampling may introduce error in the analysis as...

Download PDF file
  • EP ID EP388669
  • DOI 10.9790/1676-1301034551.
  • Views 134
  • Downloads 0

How To Cite

Engr. L. Dumkhana, Dr. D. C. Idoniboyeobu (2018). Solar PV/Battery System Analysis for Faculty of Engineering Building, Rivers State University, Port Harcourt, Nigeria.. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 13(1), 45-51. https://europub.co.uk/articles/-A-388669