STEADY-STATE HEAT REJECTION RATES FOR A COAXIAL BOREHOLE HEAT EXCHANGER DURING PASSIVE AND ACTIVE COOLING DETERMINED WITH THE NOVEL STEP THERMAL RESPONSE TEST METHOD

Journal Title: UNKNOWN - Year 2018, Vol 33, Issue 2

Abstract

At three locations in Zagreb, classical and extended thermal response test (TRT) was conducted on installed coaxial heat exchangers. With classic TR test, thermogeological properties of the ground and thermal resistance of the borehole were determined at each location. It is seen that thermal conductivity of the ground varies, due to difference in geological profile of the sites. In addition, experimental research of steady-state thermal response step test (SSTRST) was carried out to determine heat rejection rates for passive and active cooling in steady state regime. Results showed that heat rejection rate is only between 8-11 W/m, which indicates that coaxial system is not suitable for passive cooling demands. Furthermore, the heat pump in passive cooling mode uses additional plate heat exchanger where there is additional temperature drop of working fluid by approximately 1,5 °C. Therefore, steady-state rejection rate for passive cooling is even lower for a real case project. Coaxial heat exchanger should be always designed for an active cooling regime with an operation of a heat pump compressor in a classical vapour compression refrigeration cycle.

Authors and Affiliations

Tomislav Kurevija, Marija Macenić, Kristina Strpić

Keywords

Related Articles

ODREĐIVANJE POTENCIJALA POHRANJIVANJA TOPLINSKE ENERGIJE KOAKSIJALNIM BUŠOTINSKIM IZMJENJIVAČEM TOPLINE KOD PASIVNOGA I AKTIVNOGA HLAĐENJA PRIMJENOM NOVE METODE „STEP” TESTA TOPLINSKOGA ODAZIVA TLA

Tipski i prošireni test toplinskoga odaziva tla (TRT) izveden je na koaksijalnim izmjenjivačima topline na trima različitim lokacijama u Zagrebu. Tipskim testom toplinskoga odaziva određena su termogeološka svojstva tla...

PRIKAZ RUDARSTVA HRVATSKE, EUROPE I SVIJETA NA KRAJU MILENIJA

Na kraju drugog milenija rudatrstvo, temeljna grana gospodarstva mnogih država, nema dobar imidž u Hrvatskoj niti u svijetu. U članku je izložena proizvodnja i značenje rudarstva u nas i u svijetu. Analizirani su trendov...

DRILL BITS FOR HORIZONTAL WELLS

This paper underlines the importance of the correct drill bit application in horizontal wells. Afler the analysis of the peculiarities of horizontal wells and drainholes drilling techniques, advantages and disadvantages...

ODABIRANJE DIMENZIJA PODGRADA PODZEMNIH PROSTORIJA

Iz kritičkog osvrta na uobičajeni način proračuna interakcije stijene i podgradc slijedi da proračun podgradc koji se temelji na njihovim zajedničkim deformacijama nije pouzdan. Ako se, nakon šo je ugrađena podgrada, def...

MOGUĆNOST VODOOPSKRBE PODRUČJA USORE

U aluviju rijeke Usore razvijen je kvartarni šljunkoviti vodonosnik iz kojega je moguće pridobiti potrebite količine vode za vodoopskrbu područja Usore. To je plitki otvoreni vodonosnik visoke propusnosti. Debljina mu do...

Download PDF file
  • EP ID EP30203
  • DOI 10.17794/rgn.2018.2.6
  • Views 162
  • Downloads 5

How To Cite

Tomislav Kurevija, Marija Macenić, Kristina Strpić (2018). STEADY-STATE HEAT REJECTION RATES FOR A COAXIAL BOREHOLE HEAT EXCHANGER DURING PASSIVE AND ACTIVE COOLING DETERMINED WITH THE NOVEL STEP THERMAL RESPONSE TEST METHOD. UNKNOWN, 33(2), -. https://europub.co.uk/articles/-A-30203