STUDY OF UNEVENNESS HEIGHT DISTRIBUTION FOR GRAPHITE PANTOGRAPH CONTACT STRIP

Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2010, Vol 34, Issue 34

Abstract

An assumption of data distribution is of great importance because in many cases it determines the method that ought to be used to estimate the unknown parameters in the model. In this paper we performed a study of unevenness height distribution for three graphite plates, with different wear degree, used as pantograph contact strips. Using roughness diagram we determined the height, number of asperities and statistical values. With Kolmogorov test we verify the unevenness height distribution for two cases: exponential and normal distribution. We assumed a theoretical repartition, which is compared with empirical repartition. The obtain values for random variable are compared to verify the hypothesis assumed. Then we verify the equality of variance with Fischer-Snedecor test and the equality of mean with Student test for two probes which have the same repartiton. The study results of unevenness for three graphite plates used as pantograph contact strips, based on roughness diagram, let to conclusion that the unevenness height distribution vary with degree of wear.

Authors and Affiliations

Constantin-Florin OCOLEANU, Gheorghe MANOLEA, Grigore CIVIDJIAN, Alin-Iulian DOLAN

Keywords

Related Articles

ETHERNET INTERFACE FOR A SYSTEM OF AUTOMATION WITH MICROCONTROLLER

Because the Internet is becoming more widespread, there was the possibility of communication with automation systems for configuration, reprogramming or control in real time. For this, the automation system needs a physi...

Concerning the Automatic Computation of the Electrical Stresses in the High Voltage Substations during the Transient Regimes

This paper deals with an automatic computation program using a Matlab graphical user interface GUI useful to compute electrical stresses which appear in the high voltage substations; that means the parameters computation...

THE OFF-LINE DIAGNOSE OF AUTOMATIC CIRCUIT BREAKERS BY THE TIME DOMAIN AND FREQUENCY VIBRATION ANALYSIS

This paper presents a methodology for determining the operation time at opening and closing of the circuit breakers, using multi-channel sound and vibration analyzers. All the tests on the circuit breaker are made accord...

Analytical-Numerical Method for Design of a Single-Phase AC Inductors with Ferromagnetic Core

This paper proposes a more accurate design of a single-phase AC current inductors with ferromagnetic core, for given values of inductance, of peak value of current and of magnetic flux density. The procedure combines an...

 Factors Involved in Choosing LEDs for General Lighting Applications: a Critical Review

 Electric lighting accounts for 19% of electricity consumption worldwide and generates remarkable concern to get energy savings. As a modern source of light, LEDs open up a multitude of innovative lighting solutions...

Download PDF file
  • EP ID EP107967
  • DOI -
  • Views 138
  • Downloads 0

How To Cite

Constantin-Florin OCOLEANU, Gheorghe MANOLEA, Grigore CIVIDJIAN, Alin-Iulian DOLAN (2010). STUDY OF UNEVENNESS HEIGHT DISTRIBUTION FOR GRAPHITE PANTOGRAPH CONTACT STRIP. ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica, 34(34), 119-124. https://europub.co.uk/articles/-A-107967