Studying truck transmission oils using the method of thermal-oxidative stability during vehicle operation

Abstract

<p>Development of technical maintenance of transport means consists in providing their technical state at a significant level of functional operability for which the use of quality lubricants is a key requirement. Therefore, determination of technical state of truck transmission oils by the method of thermal-oxidative stability during their operation is an urgent problem.</p><p>This problem was solved and technical state of the transmission oil was studied on the basis of operational tasks and the results of their chemotologic studies. These results can be used in development of a system of vehicle maintenance and when substantiating feasibility of using concrete oil grades during operation. A procedure for studying, determining state and compliance of the working oils by their thermal-oxidative stability with operating conditions during vehicle operation has been developed. State of transmission oils was studied during vehicle operation in gearboxes of KamAZ 6520 and MAN TGA 6×4 trucks. The study of working transmission oils was conducted at following parameters: light transmission, evaporability, viscosity. The results of studies of light transmission through an oil sample and evaporability after application of the temperature regimes used in testing working oils were used in graphical and analytical representation of the coefficient of thermal-oxidative stability. Variation of the coefficient of thermal-oxidative stability of oils of respective grades depending on their relative viscosity was determined. Analysis of the obtained functions will enable development of recommendations on conformity of working oils to the conditions of their operation.</p><p>It was found that the Tedex Gear GL-4 80W90 transmission oil, used in MAN TGA 6×4 trucks, corresponds by its thermal-oxidative stability characteristics to the operating conditions. At the same time, the study of use of YUKO TО-4 80W-85 transmission oil in KamAZ 6520 trucks has shown that the oil did not demonstrate its functional capacity at runs of 8‒30 and 45 thousand kilometers. This was confirmed by analysis of the mathematical model of variation of thermal-oxidative stability of oils depending on relative viscosity, namely, by overshoot of some numerical values of the function beyond the level of 0.85 un. for the vehicle runs under study.</p>It was established that the study data can be applied to substantiation of further operation and selection of transmission oils for the studied vehicle models in transportation activities of the enterprise

Authors and Affiliations

Viktor Aulin, Andrii Hrynkiv, Sergey Lysenko, Ivan Rohovskii, Michailo Chernovol, Oleg Lyashuk, Taras Zamota

Keywords

Related Articles

Analysis of the efficiency of space­time access in the mobile communication systems based on an antenna array

<p class="Default">We performed analysis of effectiveness of various methods and criteria of space-time processing of the signals by an adaptive antenna array with a view to identifying the algorithm suitable for using i...

Investigation of force factors and stresses at singular points of plate elements in special cranes

The work addresses studying the possibilities of a numerical-analytical variant of the boundary elements method (BEM) in determining the internal force factors and stresses at singular points when bending thin isotropic...

Development of methodology for modeling the interaction of antagonistic agents in cybersecurity systems

<p>The basic concepts that form the basis of integrated modeling of the behavior of antagonistic agents in cybersecurity systems are identified. It is shown that the emphasis is largely on modeling the behavior of one of...

Development of the analytical method of the general mathieu equation solution

<p>An analytical method for solving the general Mathieu differential equation in the initial form is proposed. The method is based on the corresponding exact solution, which is found for arbitrary numerical parameters of...

Studying the efficiency of soil decontamination when using a device with the biosorbent “econadin

<p class="a">We have investigated the efficiency of soil decontamination from petroleum products using the patented perforated device of cylindrical shape with a diameter of 0.04 m, with an area of openings of 0.04 m<sup...

Download PDF file
  • EP ID EP666193
  • DOI 10.15587/1729-4061.2019.156150
  • Views 57
  • Downloads 0

How To Cite

Viktor Aulin, Andrii Hrynkiv, Sergey Lysenko, Ivan Rohovskii, Michailo Chernovol, Oleg Lyashuk, Taras Zamota (2019). Studying truck transmission oils using the method of thermal-oxidative stability during vehicle operation. Восточно-Европейский журнал передовых технологий, 1(6), 6-12. https://europub.co.uk/articles/-A-666193