Switching Control Strategy for Greenhouse Temperature-Humidity System Based on Prediction Modeling: A Simulation Study

Journal Title: Journal of Engineering and Technological Sciences - Year 2017, Vol 49, Issue 5

Abstract

It is difficult to achieve coordination control of multiple facilities that are driven by on-off actuators in a greenhouse, especially when there is more than one indoor environmental factor to consider at the same time. With the consideration of indoor air temperature and relative humidity, we propose a switching control strategy based on prediction modeling. The operation of the greenhouse system was divided into several modes according to the on-off control characteristics of the available facilities. Then, a switching diagram was designed according to the relationship between the indoor air temperature and humidity and their setting ranges. When the two indoor environmental factors reach their upper or lower limits, IARX models are used to predict them over a specified horizon for each optional mode respectively. Mode switching is carried out based on prediction results. The switching control strategy was simulated based on a mechanistic model of the greenhouse microclimate. The results show that the facilities can be coordinated very well by the proposed control strategy and it is easy to implement. The control strategy is still applicative when more facilities or more indoor environmental factors need to be taken into account

Authors and Affiliations

Zhenfeng Xu, Junjie Chen

Keywords

Related Articles

Three-Dimensional Gravity Inverse Modeling for Basement Depth Estimation Integrating Maximum Difference Reduction (MDR), Trend Surface Analysis (TSA) and Total Variation Regularization

In sedimentary basin studies, gravity data are typically used to estimate the basement topography. Gravity inversion methods are expected to be able to discriminate between continuous and discontinuous sedimentary basins...

Development of Green Pavement for Reducing Oxides of Nitrogen (NOx) in the Ambient Air

The transportation sector is the biggest contributor to air pollution in Indonesia, especially in metropolitan cities. Gases such as oxides of nitrogen (NOx) are produced during the combustion of fossil fuels in the inte...

The Effect of TiO2 Coating on Pile Penetration Depth in Clay

Pile driving tests were conducted using models of concrete piles with titanium dioxide (TiO2) coating and piles without coating. Pile surfaces coated with TiO2 become superhydrophilic, which enables water molecules in cl...

Characteristics of Rainfall-Discharge and Water Quality at Limboto Lake, Gorontalo, Indonesia

Problems of high turbidity, sedimentation, water pollution and siltation occur at Limboto Lake, Gorontalo, Indonesia. The objective of this study was to analyze the rainfall-discharge relationship and its implications fo...

Effects on Buildings of Surface Curvature Caused by Underground Coal Mining

Ground curvature caused by underground mining is one of the most obvious deformation quantities in buildings. To study the influence of surface curvature on buildings and predict the movement and deformation of buildings...