Switching on Power Harmonic Filters
Journal Title: Energy Engineering and Control Systems - Year 2018, Vol 4, Issue 2
Abstract
In modern industrial power supply systems, there is observed rapid growth of time varying nonlinear loads having low power factor. The most adequate engineering solution for reactive power compensation of the loads is using compensation units including multiple single tuned passive filters. The practice of operating multiple single tuned filter circuits in the power supply systems has shown that switching transients in the supply system can generate high overvoltages and overcurrents on the filter circuit components. Rated parameters of the filter capacitor and reactor are characterized by the certain manufacturing tolerances. So, filter tuning depends on the tolerances. The impact of the filter tuning on switching transient behaviour under harmonic filters energizing has been analysed in the study.
Authors and Affiliations
Yuriy Varetsky
Simulation of Dynamic Processes of Gas Flow in Collector Systems
By using CFD-simulation, plug length simulation of local resistance type plugged tee, which changes the flow direction, using equations of hydrodynamics was carried out. During simulation, velocity of medium in the threa...
Computer-Aided System for Monitoring and Planning of Actions to Increase Machine-Building Enterprises Energy Efficiency
The article describes mathematical model of analyses the energy use costs efficiency (depending on the type and volume of products produced by the machine-building enterprise, the consumption of certain types of energy r...
Methodical Framework of the Support and Decision-making System for the Collection and Disposal of Organic Raw Materials
Topical and important issue is the national problem of introduction of biomethane production and the Ukrainian gas transportation system. This problem can be addressed through the use of information technology based on t...
Algorithmic Method for Precision Enhancement of Paper Pulp Blade Consistometer
The article deals with the algorithmic method for precision enhancement of paper pulp blade consistometers . In the said method, the current strength in the winding of a moving coil of a magnetoelectric transducer in the...
Calculation of Expansibility Factor of Gas at Its Flow Through an Orifice Plate with Flange Pressure Tappings
The values of expansibility factor of gas were defined more accurately based on the values obtained by Seidl in CEESI using the equation of mass flowrate and on the basis of experimental data (differential pressure acros...