The choice of control parameters for regulating modes of operation of a switched reluctance motor

Abstract

The article discusses the choice of control parameters for regulating various modes of operation of a switched reluctance motor. The analysis of articles published during the 2005-2018 year a switched reluctance motors for various drives in Ukraine and abroad. The analysis showed that there is a great diversity in the choice of control parameters from different authors, and most authors do not have an analysis of transients when using selected control parameters. The author of the article in previous works used phase control for a switched reluctance motor of a mine electric locomotive with a capacity of 27 kW and a rotational speed of 1146 min-1. In order to select the optimal control parameters in this work for the specified engine, the PWM voltage was chosen as the control parameter. Transients are considered when changing the load torque in the engine mode, as well as from the engine mode to the recuperative braking mode at a constant rotation speed using the developed engine model for transients in the Simulink program of the Matlab software package. When switching from engine mode to recuperative braking, the on and off angles changed. The pulse duty rates in PWM were determined using mechanical characteristics calculated on the engine models for steady-state conditions. The results of the analysis can be used in the de-velopment of a program for the microprocessor controller.

Authors and Affiliations

L. P. Galayko

Keywords

Related Articles

Optimal control of voltage modes of low-voltage distribution electric networks with use of regulatory devices of th power transformers

An approach is proposed to control the voltage regimes of distribution electrical networks containing power transformers with noncontact on-load tap changers, which is based on the solution of the multicriteria optimizat...

Development latch short-circuit for overhead power line voltage of 110 - 150 kV

Proposed a simple design of electromechanical latch short-circuit for overhead power line voltage of 110-150 kV. For the selected constructions shows a method of calculating its technical characteristics. Experimentally...

Structure and kinematic scheme of medium voltage vacuum contactors

The structure and kinematic schemes of vacuum contactors are considered. The review of design is presented and the operation principle of medium voltage vacuum contactors by foreign manufacturers is considered.

Increasing of precision of components of magnetic field determination in steel amour of power cable is obtained

By using Chebyshev polynomials approximate expressions for determination of radial and tangential components of magnetic field intensity on the surface of power cable steel armour are obtained. The increase of precision...

On the question of the classification of the voltage relay for the protection of domestic single-phase consumers from unacceptable voltage fluctuations in the mains

A classification of voltage-sensitive relays for protection of one-phase residential electrical customers against prohibitive voltage deviation in the supply main is presented. Main indications of voltage-sensitive relay...

Download PDF file
  • EP ID EP494216
  • DOI 10.20998/2079-3944.2018.32.09
  • Views 130
  • Downloads 0

How To Cite

L. P. Galayko (2018). The choice of control parameters for regulating modes of operation of a switched reluctance motor. Вісник Національного технічного університету "ХПІ". Серія: Проблеми удосконалювання електричних машин і апаратів. Теорія і практика, 32(1308), 51-54. https://europub.co.uk/articles/-A-494216