THE EFFECT OF DOUBLE VENTURI'S STRUCTURAL PARAMETERS ON THE REINFORCEMENT VALUE AND FLOW COEFFICIENT

Journal Title: Metrology and Measurement Systems - Year 2008, Vol 15, Issue 3

Abstract

Reinforcement factor of a double Venturi is one of the more important parameters related to sensor shape and structure. The evaluation and the effect of the double Venturi's structural parameters on its value were carried out by means of the regression equation obtained from numerical simulation tests conducted by means of the Fluent program and planned experimental techniques. The presented test results indicate that the largest effect on reinforcement, within the tested field, was the throat diameter of the internal Venturi and the diffuser length of the external Venturi. The second important parameter of a double Venturi is the flow coeffcient K. The analysis of construction parameters was also carried out by means of the regression equation. The parameters which, when enlarged, cause the reduction in the flow coeffcient (K) range are: the diffuser length of the external Venturi, and the first-degree interaction between the internal diffuser length and the internal Venturi's throat diameter. Simulation test results and conclusions have been supported by experimental results.

Authors and Affiliations

ANTONI GONDEK, TADEUSZ FILICIAK

Keywords

Related Articles

CONDUCTANCE QUANTIZATION IN FERROMAGNETIC CO NANOWIRES

Room temperature electronic transport properties of ferromagnetic quantum wires have not been yet fully understood, and the role of electronic structure of magnetic atoms in the conductance quantization is still under di...

SEVERAL APPROACHES TO ADC TRANSFER FUNCTION APPROXIMATION AND THEIR APPLICATION FOR ADC NON-LINEARITY CORRECTION

The performance of current electronic devices is mostly limited by analog front-end and analog-to-digital converter's (ADC) actual parameters. One of the most important parameters is ADC nonlinearity. The correction of t...

ON-LINE INSTANTANEOUS FREQUENCY ESTIMATION AND VOLTAGE/CURRENT COHERENT RESAMPLING METHOD

An innovatory on-line method of power system frequency estimation and voltage/current signals resampling is presented. The method is designed to increase the accuracy of power system equivalent harmonic impedance estimat...

TWO-PARAMETER MEASUREMENTS AND SIGNAL CONDITIONING IN DOUBLE-CURRENT SUPPLY FOUR-TERMINAL RESISTANCE CIRCUITS

A new type of the four-terminal (4T) bridge circuit unconventionally supplied by current sources connected in parallel to opposite arms, named double current bridge (2J) is presented. It has two different outputs from bo...

A RELIABLE LOW-COST METHOD FOR ACCURATE CHARACTERIZATION OF ANTENNAS IN TIME DOMAIN

In this paper, a time domain-based approach to practical characterization of antennas is presented. The goal is to prove that time domain-based approach, after appropriate processing, represents an accurate and more prac...

Download PDF file
  • EP ID EP144598
  • DOI -
  • Views 89
  • Downloads 0

How To Cite

ANTONI GONDEK, TADEUSZ FILICIAK (2008). THE EFFECT OF DOUBLE VENTURI'S STRUCTURAL PARAMETERS ON THE REINFORCEMENT VALUE AND FLOW COEFFICIENT. Metrology and Measurement Systems, 15(3), 287-300. https://europub.co.uk/articles/-A-144598