The Effect of Field Size and Distance From the Field Center on Neutron Contamination in Medical Linear Accelerator

Abstract

Objective: Using Megavoltage photons generated by medical linear accelerator is a common modality for the treatment of malignant. The crucial problem for using photon beams >8MV is the photoneutron yields that increase the risk of secondary cancer that treated with high-energy photon beams. The contaminated neutrons produced in different components of the accelerator head and rely on many parameters. The purpose of this study was to determine the effect of field size on the neutron dose equivalent in center and far from it at the Elekta Sl 75/25 18 MV linear accelerator. Methods: Neutron dosimetry was carried out with CR-39 films with using of chemical etching technique. The measurement was done at isocenter, 25 cm and 50 cm far from it at 100 cm SSD for squared field with 5 up to 30 cm side. Results: The results revealed that the neutron dose equivalent increased with increasing field sizes especially for 5*5 cm2 field size. It was decreased with increasing distance from the isocenter. Conclusion: The effect of field size on neutron contamination depend on amount of field aperture where in small field size 5×5 cm2 less variation need for significant change but for larger field size 10×10 cm2 this variation must be larger. The contaminated neutron outside photon field is independent of field size.

Authors and Affiliations

Mahdi Jahangiri| Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran, Payman Hejazi| Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran, Seyed Mehdi Hashemi| Second Standard Dosimetry Laboratory, Karaj Institute of Nuclear Science and Technology, Karaj, Iran, Abbass Haghparast| Department of Medical Physics, Kermanshah University of Medical Sciences, Kermanshah, Iran, Bardia Hajizadeh| Medical Radiation Physics Calibration Laboratory of NRPD – Atomic Energy Organization of Iran

Keywords

Related Articles

Investigation the Concentration of Heavy Metals in the Sediment of Zayandehrood River Bed

Objective: Zayandehrood habitat has economical and environmental importance in central plateau of Iran and it performs a vital role for habitants, agriculture section and the industries which are located along river be...

The effect of microbial inoculants on physiological responses of two wheat cultivars under salt stress

Salinity is one of the most important abiotic stresses that limit crop growth and productivity. This study focuses on the effects of different strains of plant growth promoting rhizobacteria (PGPR) on the physiological...

Genetic Contribution of Grapevine (Vitis Vinifera L.) Main Yield Components in Final Yield

Objective: Yield components and genetic contribution have the most important in final yield and breeding programs of crop plants. For this purpose, 20 varieties of grapevines with Russia origin were evaluated in Urmia...

Interaction Effect of Salicylic Acid and Putrescine on Vase life of Cut Narcissus Flowers

The effects of salicylic acid (SA) and Putrescine (Put), on cut Narcissus was studied. SA (0, 100 and 200 mg l-1) and Put (0, 150 and 300 mg l-1), their combinations were tested as preservative mixture. This study was...

Effect of Oleo-Gum Resin of Ferula Assafoetida on Growth of Some Food and Crop Contaminating Microbes

Objective: The aim of this study was to determine the Minimum inhibitory concentration (MIC) and minimum fungicidal or bactericidal concentration (MFC, MBC) of oleo-gum resin of Ferula assafoetida on the growth of food...

Download PDF file
  • EP ID EP13470
  • DOI -
  • Views 385
  • Downloads 13

How To Cite

Mahdi Jahangiri, Payman Hejazi, Seyed Mehdi Hashemi, Abbass Haghparast, Bardia Hajizadeh (2015). The Effect of Field Size and Distance From the Field Center on Neutron Contamination in Medical Linear Accelerator. International journal of Advanced Biological and Biomedical Research, 3(1), 97-104. https://europub.co.uk/articles/-A-13470