The Effect of Field Size and Distance From the Field Center on Neutron Contamination in Medical Linear Accelerator

Abstract

Objective: Using Megavoltage photons generated by medical linear accelerator is a common modality for the treatment of malignant. The crucial problem for using photon beams >8MV is the photoneutron yields that increase the risk of secondary cancer that treated with high-energy photon beams. The contaminated neutrons produced in different components of the accelerator head and rely on many parameters. The purpose of this study was to determine the effect of field size on the neutron dose equivalent in center and far from it at the Elekta Sl 75/25 18 MV linear accelerator. Methods: Neutron dosimetry was carried out with CR-39 films with using of chemical etching technique. The measurement was done at isocenter, 25 cm and 50 cm far from it at 100 cm SSD for squared field with 5 up to 30 cm side. Results: The results revealed that the neutron dose equivalent increased with increasing field sizes especially for 5*5 cm2 field size. It was decreased with increasing distance from the isocenter. Conclusion: The effect of field size on neutron contamination depend on amount of field aperture where in small field size 5×5 cm2 less variation need for significant change but for larger field size 10×10 cm2 this variation must be larger. The contaminated neutron outside photon field is independent of field size.

Authors and Affiliations

Mahdi Jahangiri| Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran, Payman Hejazi| Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran, Seyed Mehdi Hashemi| Second Standard Dosimetry Laboratory, Karaj Institute of Nuclear Science and Technology, Karaj, Iran, Abbass Haghparast| Department of Medical Physics, Kermanshah University of Medical Sciences, Kermanshah, Iran, Bardia Hajizadeh| Medical Radiation Physics Calibration Laboratory of NRPD – Atomic Energy Organization of Iran

Keywords

Related Articles

Antibacterial Activity of Silver Nanoparticles Produced by Plantago Ovata Seed Extract Against Pseudomonas Aeruginosa

Objective: Development of resistance against many of the commonly used antibiotics is an impetus for further efforts to search for new antimicrobial agents. The aim of the study was determined as antibacterial activity...

In Ovo Injection of Triaminohexanoic Acid in Fowl: Gross Investigation

Objective: In recent years, amino acids are used in veterinary medicine for many purposes. They injected into hatching eggs to increase chick body weight and performance at hatch, but the adverse effects of amino acids...

Diagnosis, Treatment and Prevention of Pregnancy Toxemia in Ewes

Thin ewes or very over-conditioned ewes and ewes carrying multiple pregnancies are more likely to develop pregnancy toxemia (ketosis). Pregnancy toxemia is a metabolic disorder characterized by hypoglycemia and hyperke...

Comparing the Mental Health of Female Athlete and Non-Athlete Students in the City of Indica

Objective: The present study aimed to compare mental health of female athlete and non-athlete students in the city of Indica. The research methodology was a descriptive survey, which initially described the mental heal...

Effects of frozen diluents on storage of ram sperm

Semen collection evaluation and addition of preservatives to increase storage period of sperm are essential for successful artificial insemination. This study was conducted on 4rams (2 Ghezel Merinos and 2 Merinos Mogh...

Download PDF file
  • EP ID EP13470
  • DOI -
  • Views 378
  • Downloads 13

How To Cite

Mahdi Jahangiri, Payman Hejazi, Seyed Mehdi Hashemi, Abbass Haghparast, Bardia Hajizadeh (2015). The Effect of Field Size and Distance From the Field Center on Neutron Contamination in Medical Linear Accelerator. International journal of Advanced Biological and Biomedical Research, 3(1), 97-104. https://europub.co.uk/articles/-A-13470