The effect of recasting on corrosion of DUCINOX prosthetic alloy

Journal Title: Archiwum Odlewnictwa - Year 2009, Vol 9, Issue 3

Abstract

The effect of recasting, up to two times, Ni-Cr (DUCINOX) prosthetic alloy on its corrosion properties was carried out. The corrosion measurements were done in deoxygenated Fusayama Meyer artificial saliva solution at temperature of 37°C. In the study following electrochemical methods were used: measurement of free corrosion potential Ecor in open circuit, measurement of polarization resistance according to Stern-Geary's method and measurement of potentiodynamic characteristic in wide range of anodic polarization. In general, it can be stated that casting number weakly influence on corrosion properties of investigated alloy. At free corrosion potential there is no monotonic dependence of corrosion parameters versus casting number. However, at extreme anodic potentials monotonic changes of corrosion parameters with increasing casting number is observed. Obtained results and drawn conclusions are partially compatible with literature data.

Authors and Affiliations

L. Klimek, R. Pierzynka, T. Błaszczyk, B. Burnat, H. Scholl, S. Marciniak

Keywords

Related Articles

Laboratory grey cast iron continuous casting line with electromagnetic forced convection support

The article describes the construction of a 20 mm diameter grey cast iron ingots continuous casting laboratory line. This line is made of three main units: melting unit (induction furnace), casting unit and the pulling u...

Identification of temperature changes dynamics in selected castings as a contribution to performance life improvement

Parameters describing boundary conditions and dynamics of temperature changes during casting cooling in foundry moulds and the successive performance, especially as regards the massive cast elements, were discussed. Cons...

Silumins alloy crystallization

This paper presents the results of research, by ATD method, of hypo-, near- and hyperutectic silumins crystallization containing the following alloying additives: Mg, Ni, Cu, Cr, Mo, W, V. It has been shown that, dependi...

Influence of supply voltage frequency of induction coil on inoculation efficiency of pure aluminium structure

In paper is presented problem concerning inoculation of pure aluminium structure, which is realized mainly by intensification of liquid metal movement in mould. In aim of realization of forced movement during the crystal...

Selected parameters of moulding sands for designing quality control systems

One of the modern methods of production optimisation are artificial neural networks. Neural networks owe their popularity to the fact that they are convenient tools, which can be utilised in a wide scope of problems. The...

Download PDF file
  • EP ID EP72003
  • DOI -
  • Views 76
  • Downloads 0

How To Cite

L. Klimek, R. Pierzynka, T. Błaszczyk, B. Burnat, H. Scholl, S. Marciniak (2009). The effect of recasting on corrosion of DUCINOX prosthetic alloy. Archiwum Odlewnictwa, 9(3), 67-70. https://europub.co.uk/articles/-A-72003