The Effect of Slice Thickness on the Volume Estimations Performed by Using Cone Beam CT
Journal Title: Cumhuriyet Dental Journal - Year 2018, Vol 21, Issue 3
Abstract
Objective: The purpose of this study is to investigate possible effects of the slice thickness on volume estimations with CBCT. Materials and Methods: Intraosseous cavities representing bone defects on femoral condyles of bovines were scanned by CBCT. Consecutive slices at 0.1 mm, 0.2 mm, 0.3 mm, 0.4 mm, 0.5 mm, 1 mm, 2 mm, 3 mm, 4 mm, and 5 mm thickness were used to estimate the volumes of the cavities using Cavalieri principle of stereological methods then compared with the volumes obtained by Archimedean principle. Results: The volumes estimated by Cavalieri principle in 0.1, 0.2, and 0.3 mm thickness slices were consistent with the volumes obtained by Archimedean principle (p>0.05). For all the defects on the CBCT images, the volumes of the defects which were calculated with Cavalieri principle in 0.1, 0.2, and 0.3mm slice thickness were found to be consistent with the actual volumes, however, the volumes that were calculated in 0.4 mm, 0.5 mm, 1 mm, 2 mm, 3 mm, 4mm, and 5 mm slice thickness were found to differ from the actual volumes. Conclusion: When volume calculations were made by Cavalieri principle, the thinnest slice section should be chosen to make calculations consistent with actual volumes.
Authors and Affiliations
Seval Bayrak, Omer Said Sezgin, Saadettin Kayıpmaz, Gamze Çan
Historical Development and Properties of Platelet Concentrates in Dentistry
Platelets are playing a very important role in wound healing and hemostasis and are among the potential cells of regenerative therapy due to the growth factors and cytokines they contain. This has increased the interest...
The Comparison of Shear Bond Strenght of Different Bulk-Fill Composites to a Bioactive Dentine Substitute
Objective: The aim of this research was to compare shear bond strength(SBS) of various bulk-fill composites(BFC) to Biodentine(BD) with different time intervals. Materials and Methods: 300 cyclindrical acrylic blocks w...
Evaluation of Postoperative Pain After Using Different File Systems: A Randomized Clinical Study
Objectives: This study evaluated the effect of instrumentation techniques on the postoperative pain after single-visit root canal treatment. Materials and Methods: Sixty patients having an indication of endodontic treatm...
Accuracy of digital panoramic radiographs on the vertical measurements of dental implants
Objectives: Panoramic radiography (PR) is the most commonly used technique to evaluate the dental and associated structures. The aim of this study was to determine the accuracy of panoramic radiographs (PRDs) in planning...
Kompomerin Kalsiyum Silikat Esaslı Simanlara Olan Makaslama Bağlanma Dayanımı
Amaç: Bu in vitro çalışmanın amacı, Biodentine® ve Imicrly MTA'nın bir kompomer materyaline makaslama bağlanma dayanımını karşılaştırmak ve farklı sertleşme sürelerinin bağlanma dayanımına olan etkisini incelemektir.Gere...