The Electromagnetic Ballistic Hazards Faced by Fire Service Officers While on Duty

Journal Title: Safety & Fire Technology - Year 2017, Vol 46, Issue 46

Abstract

Aim: Static magnetic fields (SMF) can cause metal (ferromagnetic) objects to move and thus pose a serious hazard for the utilities and the people who are close to the source of strong SMF. These kinds of electromagnetic hazards are identified as “flying objects” or “ballistic hazards”. The aim of this study was to analyse the conditions in which electromagnetic ballistic hazards can occur during the operations of Fire Service officers (rescue, firefighting, reconnaissance/inspection and evacuation drills) and also to test personal firefighter equipment and rescue equipment for SMF susceptibility.Project and methods: SMF susceptibility was tested for both personal firefighter equipment and fire-engine rescue equipment. The equipment to be tested was selected based on study visits to fire and rescue departments, and on the basis of interviews with firefighters, and also based on an analysis of the laws governing the functioning of the State Fire Service, as well as commonly available training materials. Both the personal firefighter equipment and fire-engine rescue equipment were subjected to experimental testing for SMF susceptibility. A ferrite permanent magnet with a minimum remanence of 0.37 T was used for the testing. Field testing involved the observation of the magnet’s location, with the magnet located unconstrained within a distance of 5-10 cm from the tested firefighter equipment. Results: We have found that personal firefighter equipment is only moderately susceptible to SMF, while pieces of rescue equipment show higher susceptibility. Furthermore, we have concluded that strong SMF sources, such as, especially, magnetic resonance imaging scanners and spectrometers, magnetic grippers and separators, might pose ballistic hazards in their surroundings, causing, for instance, damage to the equipment, bodily injuries, or even death. Firefighters engaging in operations near magnetic resonance imaging scanners or spectrometers are very likely to be exposed to these kinds of hazards (usually in medical centres and research institutes), since the immediate deactivation of the SMF of these devices is impracticable in emergencies, as it requires complex procedures to be followed. Conclusions: The Regulation of the Ministry of the Interior governing the safety of firefighters on duty does not specify any safety requirements for operations in the proximity of strong SMF sources. The identification, signage and elimination of hazards should be discussed during firefighters’ training and exercises.

Authors and Affiliations

Wiesław Leszko, Krzysztof Gryz

Keywords

Related Articles

Przegląd danych statystycznych dotyczących pożarów na Ukrainie

Cel: Celem artykułu jest przeprowadzenie przeglądu porównawczego światowych i ukraińskich statystyk pożarów oraz wyznaczenie na jego podstawie głównych kierunków badań analitycznych w zakresie ochrony przeciwpożarowej...

An Analysis of the Destructive Influence of Water Saturation on the Durability of Concrete Exposed to a Fire

Aim: The purpose of this paper is to present the results of a study involving concrete, containing sanitary ceramic waste as an aggregate, in context of resistance properties to high temperat...

Automaty komórkowe w modelowaniu ewakuacji

PL Cel: Przedstawienie i omówienie modeli automatów komórkowych wykorzystywanych w oprogramowaniu do modelowania ewakuacji i zjawisk jej towarzyszących. Wprowadzenie: Bezpieczeństwo w budynkach i obiektach budowlanych ob...

Zwiększenie skuteczności gaszenia pożarów metodą gazową z wykorzystaniem fali uderzeniowej

Cel: Określenie parametrów mających na celu zwiększenie skuteczności gaśniczej CO2 i N2 oraz mocy fali uderzeniowej przy ich jednoczesnym zastosowaniu do gaszenia płomienia dyfuzyjnego n-heptanu C7 H16. Określenie właś...

Зависимость распределения воды от коэффициента расхода для выбранных спринклеров ESFR

Цель: Целью данной статьи было представление результатов лабораторных испытаний выбранных спринклеров быстрого реагирования диаметром 20 мм, так называемых ESFR (Early Supression Fast Response). Спринклеры были протестир...

Download PDF file
  • EP ID EP265025
  • DOI 10.12845/bitp.46.2.2017.1
  • Views 62
  • Downloads 0

How To Cite

Wiesław Leszko, Krzysztof Gryz (2017). The Electromagnetic Ballistic Hazards Faced by Fire Service Officers While on Duty. Safety & Fire Technology, 46(46), 12-27. https://europub.co.uk/articles/-A-265025