The Impact of a Power Electronics Converter in Phase Failure Work on the Power System Network

Journal Title: Acta Energetica - Year 2016, Vol 28, Issue 3

Abstract

The paper presents the impact of phase failure work on power converters. The study includes a three-level NPC inverter (Neutral Point Clamped), controlled by Voltage Oriented Control (VOC). The NPC converter integrates renewable energy sources with the power grid. The article includes a discussion about the causes of phase failure work and an analysis of the converter’s failure and its impact on the power grid. The simulations were performed in MATLAB/Simulink. The study also includes the concept of an integrated protection for IGBTs, controlled by the DSP microprocessor system.

Authors and Affiliations

Dariusz Zieliński, Katarzyna Przytuła

Keywords

Related Articles

Design of Transformers

In this paper the basic designing of high voltage power transformers has been described. The layout and construction of a high voltage and low voltage winding of transformers has been determined. The designing of a tank...

Resonant Conditions in a Node with an SVC Compensator

The primary purpose of installing static shunt compensators in power grids is to improve the voltage conditions. Additional reactive power sources increase the system’s voltage stability and enable faster system recovery...

Simplified Distribution Grid Modelling for Connection Analyses

This paper considers the modelling of medium and low voltage grids for the purpose of connection studies by distribution grid operators. Possible simplifications in grid modelling are discussed, which are acceptable from...

Influence of Power System on Operation of an HVDC Link. A Case Study

An HVDC link enables power and energy exchange between unsynchronised power grids. Large possibilities of controlling active power flows through such systems enable commercial transfers, as well as emergency power balanc...

Maximisation of Combined Cycle Power Plant Efficiency

The paper presents concepts for increasing the efficiency of a modern combined cycle power plant. Improvement of gas turbine performance indicators as well as recovering heat from the air cooling the gas turbine’s flow s...