Abstract
For the operation of the static power converters, the experience of an expert is absolutely necessary for competitive operation. Minor faults or defects of the elements of the static power converters can lead to ravaging effects both for the other components as well as other equipment from their operating system. The paper proposes a diagnosis method based on the analytic model which investigates the output waveforms of a three-phase rectifier supplying two types of loads: a passive RLC load and a variable DC drive. Two types of possible faults of the switches are considered: interrupted and short circuit. For identifying the defective components, the waveforms corresponding for different faults are stored in an information database in order to be compared with the ones corresponding to normal operation.. Another solved problem in this article refers to the influence’s analysis of the defect propagation in the driving system. There are analyzed the waveforms corresponding of the different faults for different types of loads including a passive RLC load and a variable DC drive. For the both types of faults, important oscillations of the output voltage of the static power converter are noticed which can damage the load, but also, determine the additional stress to other healthy switches.
Authors and Affiliations
Virginia IVANOV, Maria BROJBOIU, Sergiu IVANOV
STATIC VOLTAGE SOURCE USE TO SUPPLY PARTIAL DISCHARGE MEASURING CIRCUITS AT INSTRUMENT TRANSFORMERS
The paper presents the implications of static voltage source use in the partial discharge (PD) measuring circuit at instrument transformers. The economic advantages deriving from the use of such sources must be correlate...
Effect Assessment of TCSC on Algerian Transmission Line Protected by IDMT Directional Overcurrent Relay
The paper presents the effect of apparent reactance and injected voltage by series Flexible AC Transmission System (FACTS) i.e. Thyristor Controlled Series Capacitor (TCSC) on transmission line high voltage protected...
Optimal Heating Time for Cylindrical Items Removal from the Shaf
For easy removal of cylindrical items from the shaft, they are heated on their external cylindrical surface for thermal dilatation. The best result is obtained if the temperatures gradient inside the item is highest on t...
Numerical Models for Electric Train Energy-Efficient Operation
The paper begins by presenting structure of the electric drives with traction induction motor used on locomotive fed from AC line. Are emphasized the main components of such a drive system: the main electric circuits...
Modeling Three-Phase Short-Circuits for Radial Distribution Systems
Monitoring radial distribution systems in shortcircuit conditions represents a quite important issue of electric power networks supplied by renewable sources. The method presented in the paper aims to establish in labora...