THE RESONANT OVERVOLTAGE IN NON-SINUSOIDAL MODE OF MAIN ELECTRIC NETWORK

Abstract

Purpose. The resonant overvoltage arises in main electrical networks as a result of random coincidence of some parameters of circuit and its mode and it may exist for a relatively long time. Therefore, the traditional means of limitation of short duration commutation surges are not effective in this case. The study determines conditions of appearance and development of non-sinusoidal mode after switching idle autotransformer to the overhead line of extra high voltage. The purpose of the paper is to choice measures for prevention overvoltage, too. Methodology. The study has used the result of extra high voltage line testing, the methods of electric circuit theory and the simulation in the MATLAB & Simulink package. Results. The simulation model of the extra high voltage transmission line for the study of resonant non-sinusoidal overvoltage is developed. The conditions for the appearance of resonant circuits in the real power line are found and harmonic frequency in which overvoltage arises are obtained. The study proposes using the controlled switching device as a measure to prevent resonance surges and determines the appropriate settings. Originality. The expression for calculation of resonant length of extra high voltage line was derived. The special investigation of processes in the resonant circuit of the extra high voltage transmission line for higher harmonic components of voltage is carried out. The program of switching for control apparatus that prevents non-sinusoidal overvoltage has been developed at the first time. Practical value. The using of the proposed settings of controlled switchgear will prevent the occurrence of hazardous resonant surge on higher harmonic components of voltage.

Authors and Affiliations

V. G. Kuznetsov, Yu. I. Tugay, V. V. Kuchanskiy, Yu. G. Lyhovyd, V. A. Melnichuk

Keywords

Related Articles

VALVE INDUCTION GENERATORS OF RADIAL EXCITATION WITH COMBINED WINDINGS

The design and principle of operation of inductor generators with combined windings are described. The theoretical substantiation of advantages of considered generators is presented. The data of experimental investigatio...

AN ARMATURE WINDING PARAMETER CALCULATION TECHNIQUE FOR AN AUTOMOTIVE COMPOSITELY EXCITED GENERATOR

The paper deals with problems of determining armature reaction inductance in the longitudinal and transverse axes of an induction automotive generator. By means of a developed technique, armature winding parameters for a...

A NEW HYPOTHESIS AND PHYSICAL BASES OF ORIGIN OF ROSARY LIGHTING IN THE ATMOSPHERE OF EARTH

Purpose. Development and scientific ground of new hypothesis of origin of rosary lightning (RL) is in the air atmosphere of Earth. Methodology. Electrophysics bases of technique of high (ever-higher) impulsive voltage an...

NUMERICAL SIMULATION OF SPARK DISCHARGE CHARACTERISTICS IN LIQUID NITROGEN

In MHD approximation, a mathematical model of spark discharge in liquid nitrogen is worked out on the basis of data generalization pertaining to thermodynamical functions and mass-transfer coefficients in a wide paramete...

EXPERIMENTAL APPROBATION OF AN ELECTRODYNAMIC DIRECT ELECTRIC SYSTEM FOR EXTERNAL AUTOMOBILE BODY REPAIR

The article presents results of experimental research on an electrodynamic system with direct current flow for external automobile body repair. A possibility of specifying the direction of increasing magnetic pulse attra...

Download PDF file
  • EP ID EP486252
  • DOI 10.20998/2074-272X.2018.2.12
  • Views 79
  • Downloads 0

How To Cite

V. G. Kuznetsov, Yu. I. Tugay, V. V. Kuchanskiy, Yu. G. Lyhovyd, V. A. Melnichuk (2018). THE RESONANT OVERVOLTAGE IN NON-SINUSOIDAL MODE OF MAIN ELECTRIC NETWORK. Електротехніка і Електромеханіка, 0(2), 69-73. https://europub.co.uk/articles/-A-486252