Theoretical analysis of a vapour compression refrigeration system with R134a, R290, R600a & various ratio of R290/R600a
Journal Title: International Journal for Research in Applied Science and Engineering Technology (IJRASET) - Year 2016, Vol 4, Issue 6
Abstract
Though the global warming up potential of HFC134a is relatively high, it is affirmed that it is a long term alternative refrigerants in lots of countries. The different environmental friendly refrigerants of either HC & HFC class.HCs have zero ODP and very low GWP whereas HFCs have zero ODP but a higher GWP. When R-134a was replaced with blending of HCs refrigerant the COP of the system improved. In this paper consider the Theoretical analysis of R134a, R290, R600a & various ratios of R290/R600a refrigerants. The present investigation has been done for evaporator and condenser temperatures in the range of-10oc and 40oc respectively. The results indicate that the refrigerant blend (R600a/R290) with 70/30 mass fraction was found to be the most suitable alternative among refrigerants tested for R134a.
Authors and Affiliations
P. Kannan, A. Manivanana
An Energy Efficient Multichannel Mac Protocols To Convey Bursty Data By Y-MAC
As the use of wireless sensor networks (WSNs) becomes prevalent, node density tends to increase. This poses a new analysis for Medium Access Control (MAC) protocol design. Although conventional MAC protocols achieve low...
slugDesigning High Performance Adder Circuit Using Output Prediction Logic-Opl Technique
With the continuously increasing demand for low power & high speed VLSI circuits the brain storming among the scientists, inventors & researchers to find the techniques required to design such high performance circuits...
Savoir-faire malware tracking down in Delay Tolerant Networks
With the universal presence of short-range connectivity technologies (e.g., Bluetooth and, more recently, Wi-Fi Direct) in the consumer electronics market, the delay tolerant-network (DTN) model is becoming a viable alt...
A Review on Progressive Collapse Analysis.
Progressive collapse of building is initiated when one or more vertical load carrying members particularly columns are seriously damaged or collapsed during any of the abnormal event. Once a column is failed the buildin...
slugDesigning a Model for Web Page Generation Using Repository of Templates
Software engineering is the art of Science containing software development life-cycle. It has different models which are used for devolving any type of software with each model having its own life-cycle. Similar to soft...