Thermo-physical evaluation of an ultra-low-energy family house
Journal Title: Вісник Національного університету "Львівська політехніка". Серія "Теорія та практика будівництва" - Year 2016, Vol 0, Issue 844
Abstract
Ultra-low-energy house is a term known very well to engineers and architects all over the world. In these times of minimizing an energy loads and negative emissions, energy efficient houses are one of the best ways to meet European “20-20-20” targets. The main topic of this paper is to create a building envelope assessment of an ultra-low-energy family house designed for Slovak Republic climate. Family house was designed taking in account architectural, environmental and constructional requirements of today´s European directives focusing on energy performance and energy efficiency. Ultra-low-energy house was evaluated in one dimensional thermo-physical software TEPLO. The Passive House is not an energy standard but an integrated concept assuring the highest level of comfort. The integrated concept doesn't contain any numerical values and is valid for all climates. This definition shows that the Passive House is a fundamental concept and not a random standard. Ultra-low-energy building have not been “invented” by anyone – in fact, this principle was discovered. Thermal comfort is achieved to a maximum extent through passive measures (insulation, heat recovery, passive use of solar energy and internal heat sources). Results of this project are displayed in numbers as well as in graphic figures. Our goal was to find out how the designed building will perform energetically and environmentally so we could predict and minimize environmental load on nature and society in case of its actual realization.
Authors and Affiliations
P. Turcsanyi, A. Sedlakova
ЗБІРНІ КАРКАСИ БАГАТОПОВЕРХОВИХ БУДИНКІВ З НЕРЕГУЛЯРНОЮ СІТКОЮ І ЗМІННОЮ ВИСОТОЮ ПОВЕРХІВ
In the construction of multi-storey buildings for different purposes, for many previous decades mostly typical prefabricated frame with a regular grid of columns and a constant height a floors were used. Such typical pre...
Wind action on the building faсade and Its influence on ventilation heat losses
A significant factor affecting of indoor climate and energy consumption in buildings is the air exchange rate. In correlation method is used mostly stationary outdoor climatic conditions specified in the standards - cons...
The air channel function in real life – insulation against rising damp in historical buildings
The purpose of the research is to find adequate solution against rising damp in historical buildings. The improvement in this case is the use of ventilated air channels. A special group of historical buildings are church...
The use of social marketing to the promotion of energy-efficient construction
Energy-efficient buildings or passive in the coming years should become a standard in Poland and Europe. Energy-efficient buildings are generally more expensive than traditional, so there are some psychological barriers...
Вплив внутрішніх температури і вологовмісту повітря операційних чистих кімнат на ексергетичний ККД центральної прямотечійної системи кондиціювання повітря
n the modern air conditioning systems, important place are occupied by equipment and processes, the objective estimation of value of its energy perfection can be defined only on the basis of exergetic analysis. Innovatio...