Вплив внутрішніх температури і вологовмісту повітря операційних чистих кімнат на ексергетичний ККД центральної прямотечійної системи кондиціювання повітря

Abstract

n the modern air conditioning systems, important place are occupied by equipment and processes, the objective estimation of value of its energy perfection can be defined only on the basis of exergetic analysis. Innovation mathematical research model of the implemented central straight flow air conditioning system for operation cleanrooms in order to computer’s estimation its energy effective by virtue of exergetic output-input ratio depending on different factors, which have influence on its work, was described in this article. The dependence of exergetic output-input ratio for chosen air conditioning system on parameters of indoor air, namely temperature and moisture content was defined thanks to this model. It is found, that there is no effect of moisture content on exergetic output-input ratio of the system. It is shown that the implemented air conditioning system should be preferably used at lower indoor air temperatures, namely, for example = 25 °С, and at as higher temperature difference between indoor and supplied air as it possible, for example, 9,0 °С, that will give the opportunity to gain the highest exergetic output-input ratio = 2,56, which means to gain the most advantageous economical variant of exploitation of implemented air conditioning system.

Authors and Affiliations

D. Harasym, V. Labay

Keywords

Related Articles

Energy potential of atrium space in ventilation system

The content of paper is energy analysis of ventilation system with using energy potential of atrium space. The aim of case study is to analyze energy potential of air preheating in atrium space and its utilisation in mec...

Investigation of indoor air quality and its impact on human activity - case study

This paper presents the partial results of human presence impact on indoor air quality in a monitored office room. Indoor air temperature, relative humidity and carbon dioxide concentration are recorded in the investigat...

ЕКСПЛУАТАЦІЙНИЙ СТАН, РЕКОНСТРУКЦІЯ ТА РЕЗУЛЬТАТИ ВИПРОБУВАНЬ РЕКОНСТРУЙОВАНОГО АВТОДОРОЖНЬОГО ШЛЯХОПРОВОДУ

The small and medium span bridges constructed in the 50-60s of the last century with span structures of prefabricated reinforced concrete beams according to the typical project of 1956 year currently do not meet modern e...

THE INFLUENCE OF VERTICAL STIFFENERS ON THE STIFF CHARACTERISTICS OF SILO CAPACITIES FOR GRAIN STORAGE

The paper deals with the behavior of cylindrical steel capacity under the load with different number of vertical stiffeners. It was studied both short constructions with the clamp in all points and relatively tall constr...

ON ANCHORING OF THE LONGITUDINAL TENSILE REINFORCEMENT IN REINFORCED CONCRETE BEAMS WITHOUT PRE-STRESSING

The character of oblique cracking is significantly influenced by the method and reliability of anchoring of the longitudinal tensile reinforcement on the hinge support beams. In many experimental researches the lack of a...

Download PDF file
  • EP ID EP230169
  • DOI -
  • Views 163
  • Downloads 0

How To Cite

D. Harasym, V. Labay (2016). Вплив внутрішніх температури і вологовмісту повітря операційних чистих кімнат на ексергетичний ККД центральної прямотечійної системи кондиціювання повітря. Вісник Національного університету "Львівська політехніка". Серія "Теорія та практика будівництва", 0(844), 34-40. https://europub.co.uk/articles/-A-230169