Вплив внутрішніх температури і вологовмісту повітря операційних чистих кімнат на ексергетичний ККД центральної прямотечійної системи кондиціювання повітря

Abstract

n the modern air conditioning systems, important place are occupied by equipment and processes, the objective estimation of value of its energy perfection can be defined only on the basis of exergetic analysis. Innovation mathematical research model of the implemented central straight flow air conditioning system for operation cleanrooms in order to computer’s estimation its energy effective by virtue of exergetic output-input ratio depending on different factors, which have influence on its work, was described in this article. The dependence of exergetic output-input ratio for chosen air conditioning system on parameters of indoor air, namely temperature and moisture content was defined thanks to this model. It is found, that there is no effect of moisture content on exergetic output-input ratio of the system. It is shown that the implemented air conditioning system should be preferably used at lower indoor air temperatures, namely, for example = 25 °С, and at as higher temperature difference between indoor and supplied air as it possible, for example, 9,0 °С, that will give the opportunity to gain the highest exergetic output-input ratio = 2,56, which means to gain the most advantageous economical variant of exploitation of implemented air conditioning system.

Authors and Affiliations

D. Harasym, V. Labay

Keywords

Related Articles

COLLAPSING OF THE REINFORCED CONCRETE ROOF BEEM DESIGNED FOR THE INDUSTRIAL BUILDDING. ITS CAUSES, WORKING CONDITIONS AND CONDITIONS FOR SAFETY OF REMAINING ROOF BEAMS

The project of the production house features the design of concrete roof. The roof is composed of typical precast reinforced concrete beams: single-slope (for ending spans) and double-slope (for middle span). The beam ty...

TO THE QUESTIONNAIRE OF THE OPERATING CONDITION OF SPAN CONSTRUCTIONS OF ROAD BRIDGES IN WESTERN AREAS OF UKRAINE

By using the examples of large – scale inspections of iron – concrete bridges the defects and damaqes of elements, the degradation of structural materials are shown. The examples of structure imperfection, tipical defect...

ON ANCHORING OF THE LONGITUDINAL TENSILE REINFORCEMENT IN REINFORCED CONCRETE BEAMS WITHOUT PRE-STRESSING

The character of oblique cracking is significantly influenced by the method and reliability of anchoring of the longitudinal tensile reinforcement on the hinge support beams. In many experimental researches the lack of a...

МЕТОДИКА ДОСЛІДЖЕНЬ ЗАЛІЗОБЕТОННИХ БАЛОК З ПОШКОДЖЕННЯМИ, ОТРИМАНИМИ ЗА ДІЇ НАВАНТАЖЕННЯ

The research of reinforced concrete beams, in which there is some damage or defects are scare. This is especially applies to studies in which defects arise under the influence of the load, which is due to the complexity...

STRENGTHENING OF THE REINFORCED CONCRETE TANK AFTER FAILURE

The paper describe an interesting case of rectangular reinforced concrete tank strengthening. Due to errors in reinforcement design, the long walls of the tank were seriously cracked and starts to leak during the water t...

Download PDF file
  • EP ID EP230169
  • DOI -
  • Views 159
  • Downloads 0

How To Cite

D. Harasym, V. Labay (2016). Вплив внутрішніх температури і вологовмісту повітря операційних чистих кімнат на ексергетичний ККД центральної прямотечійної системи кондиціювання повітря. Вісник Національного університету "Львівська політехніка". Серія "Теорія та практика будівництва", 0(844), 34-40. https://europub.co.uk/articles/-A-230169