Abstract

Regular monitoring of the condition of transformer is not only economical, but also adds to increased reliability. In the past, maintenance of transformers was done based on a pre-determined schedule. With the advancement of communication technology now it is possible to receive fault information of transformer through GSM technology. This paper presents the implementation of Global Systems for Mobile Communication (GSM) in detecting fault in microcontroller based power transformer. The design was achieved with microcontroller and other integrated circuit. The microcontroller thus monitors the phases of the distribution lines from the transformer for power failure, over-voltage, under-voltage and total power outage. At fault detection, the system will automatically send a notification message to the power station management, about the conditions of the transformer, its location and the transformer site code for easy location and quick response for possible power restoration.

Authors and Affiliations

Nweke Chisom. B, Iroegbu Chibuisi, Ogechikanma Ihekweaba, Ifenkwe Clement. E

Keywords

Related Articles

Light Weight Bricks Using Waste EPS Beads

Demand of construction materials is increasing day by day, Technology has improved a lot in construction techniques of structures. Earlier structures were constructed with heavy materials, but in present time of constru...

slugAndroid Environment Security Through Penetration Testing Methodology

The fluidity of application markets complicate Smartphone security. Although recent efforts have shed light on particular security issues, there remains little insight into broader security characterist...

A review of genetic algorithm for metal cutting processes and a research agenda

Quality of finished product manufactured by metal cutting process depends on various machining factors. Similarly the chemical composition of work piece material also plays important role .So before processing we must k...

A survey on Intrusion Detection System by Using Data Mining Based on Class-Association-Rule Mining Using GNP

There is often the need to update an installed Intrusion Detection System (IDS) due to new attack methods or upgraded computing environments. Since many current IDSs are constructed by manual encoding of expert knowledg...

Security Problems and Their Defenses in TCP/IP Protocol Suite

The Transmission Control Protocol/Internet Protocol (TCP/IP) is combination of different protocols at various layers.TCP/IP is the basic communication language or protocol of the Internet and private networks either an...

Download PDF file
  • EP ID EP18486
  • DOI -
  • Views 300
  • Downloads 10

How To Cite

Nweke Chisom. B, Iroegbu Chibuisi, Ogechikanma Ihekweaba, Ifenkwe Clement. E (2014). Using GSM to Detect Fault in Microcontroller Based Power Transformer. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 2(8), -. https://europub.co.uk/articles/-A-18486