Using the three-frequency bioimpedance measurement for inhomogeneous biological objects
Journal Title: Вісник НТУУ КПІ. Серія Радіотехніка, Радіоапаратобудування - Year 2013, Vol 0, Issue 54
Abstract
Introduction. The possibility of using three-frequency bioimpedance to determine the structure of a biological object with two inhomogeneities are investigated. Formulation of the problem. The veracity of the determination the internal structure of inhomogeneous biological objects using three-frequency bioimpedance measuring method are studied insufficiently. Methods of research and analysis of the results. Describes the method of determining the possibility of using the three-frequency bioimpedance measuring method for determination the internal structure of inhomogeneous biological objects. Conclusion. Studies indicate the usefulness of three-frequency bioimpedance measuring method just for a rough determination of the parameters of the biological object.
Authors and Affiliations
G. Timoshenko
Professional competence – condition of the produce professional activity specialist
Essence term “professional competence of the technical specialist” is reveal. The learn methodic of the technical discipline connected with forming professional competence for the student of higher technical institutes i...
Target detection in pulse-Doppler radar based on multi-scanning signal integration
Introduction. Development of multi-scanning signal integration algorithms for pulseDoppler radars which are widely used in practice is of great practical importance. Problem statement. The problem of multi-scanning signa...
Choice of maintaining the resonant mode piezoelectric transducer
Analyzed the possible schemes for constructing ultrasonic generators with feedback, justified the choice of maintaining the resonant mode ultrasonic transducer.
The reliability parameters definition in radioelectronic devices automated designing systems
The reliability parameters calculating problems for radioelectronic devices determined by thermal modes are considered. It is shown that such calculations should be based on temperature definition methods for separate co...
Analysis of character of dependence between pulse pressure in an artery and amplitude of a pulse signal non invasive registered
Dependences of amplitude of a pulse signal registered by a non-invasive method from pulse pressure in an artery are studied. It is shown, that for ranges of the pressures concerning to people, with an adequate accuracy i...