Validation and reproducibility of the Heidelberg Edge Perimeter in the detection of glaucomatous visual field defects

Journal Title: International Journal of Ophthalmology - Year 2019, Vol 12, Issue 4

Abstract

"AIM: To validate the ability of the Heidelberg Edge Perimeter (HEP) in detecting glaucomatous visual field (VF) defects compared to the Octopus Visual Field (OVF) Analyzer and to determine the test-retest repeatability of both modalities. METHODS: This prospective, cross-sectional study was conducted at Wills Eye Hospital, Philadelphia, PA. Glaucoma subjects and unaffected controls underwent VF testing using HEP standard automated perimetry (SAP) III 30-2 Adaptive Staircase Thresholding Algorithm (ASTA) FAST protocol and OVF G-TOP white-on-white strategy. Testing order was randomized. Pearson’s correlation coefficient was calculated for both mean deviation (MD) and pattern standard deviation/square root of loss of variance (PSD/sLV). Receiver operating characteristic (ROC) curves were used to determine the diagnostic abilities of both modalities. Glaucoma subjects returned for repeat testing and intraclass correlation coefficients (ICCs) were calculated to assess test-retest repeatability. RESULTS: Seventy-nine subjects with glaucoma and 36 unaffected controls were enrolled. HEP and OVF were significantly correlated for both MD (r=-0.84; P<0.01) and PSD/sLV (r=0.79; P<0.01). Areas under the ROC curves (AUCs) were also comparable between HEP and OVF for both MD (0.74 and 0.79, respectively; P=0.26) and PSD/sLV (0.74 and 0.82; P=0.08). ICC was high for both HEP (0.96 for MD, 0.95 for PSD/sLV) and OVF (0.82 and 0.88, respectively). Mean test duration (min) was significantly shorter for OVF (2.63) compared to HEP (5.15; P<0.01). CONCLUSION: HEP and OVF show strong correlation for both MD and PSD/sLV, and have similar validity for detecting glaucoma. The test-retest repeatability is high for both HEP and OVF, however the average testing duration of HEP is significantly longer than that of OVF."

Authors and Affiliations

Jonathan S. Myers

Keywords

Related Articles

Prognostic factors of short-term outcomes of intravitreal ranibizumab in diabetic macular edema

"AIM: To evaluate the prognostic factors for short-term visual and anatomical improvement of intravitreal ranibizumab (IVR) for diabetic macular edema (DME). METHODS: Fifty-one eyes from 35 patients that received three c...

Accommodation in human eye models: a comparison between the optical designs of Navarro, Arizona and Liou-Brennan

"AIM: To simulate and compare accommodation in accommodative and non-accommodative human eye models. METHODS: Ray tracing and optical design program was used. Three eye models were designed and studied: the Navarro, the...

Treatment of myopic foveoschisis via macular buckling and vitrectomy

The aim of the present study was to evaluate the efficacy and safety of the treatment of myopic foveoschisis patients using the macular buckling with L-shaped titanium plate and silicon sponge combined with vitrectomy. T...

Novel mutation in OCRL leading to a severe form of Lowe syndrome

"AIM: To investigate the phenotype and genotype of a family with X-linked recessive Lowe syndrome. METHODS: All the members in the Chinese pedigree underwent comprehensive ophthalmologic and systemic examinations. Genomi...

Novel mutations in CRYBB1/CRYBB2 identified by targeted exome sequencing in Chinese families with congenital cataract

"AIM: To summarize the phenotypes and identify the underlying genetic cause of the CRYBB1 and CRYBB2 gene responsible for congenital cataract in two Chinese families. METHODS: Detailed family histories and clinical data...

Download PDF file
  • EP ID EP616556
  • DOI 10.18240/ijo.2019.04.08
  • Views 42
  • Downloads 0

How To Cite

Jonathan S. Myers (2019). Validation and reproducibility of the Heidelberg Edge Perimeter in the detection of glaucomatous visual field defects. International Journal of Ophthalmology, 12(4), 577-581. https://europub.co.uk/articles/-A-616556