Variability among 2D and 3D methods of calculating mitral valve area: a comparative study with pressure half time method
Journal Title: Nepalese Heart Journal - Year 2017, Vol 14, Issue 2
Abstract
Background and Aims: The aim of this study was to evaluate the feasibility, reproducibility and accuracy of Live Three dimensional Echocardiography (3DE), Two dimensional Echocardiography (2DE) and Three dimensional Xplane Echocardiography (3D Xplane) for the estimation of mitral valve area (MVA) and to assess which method has the best agreement with the MVA non- invasively evaluated by the Pressure half time (PHT) method in isolated rheumatic mitral valve stenosis (RMVS). Methods: In 40 patients with isolated RVMS in sinus rhythm (29 female) MVA was determined by Doppler PHT method and compared with measurements obtained by 2DE, Live 3DE and 3D Xplane method. All measurements were performed by two independent observers. Results: For both observers mean MVA was calculated minimum with 3DE (observer 1: 0.68±0.19, observer 2: 0.68±0.19 ). Intraobserver variability was least with 3D Xplane method (observer 1 cv 0.23 , observer 2 cv 0.23). Although there was no signifcant interobserver variability for each method, it was least for MVA by 3D Xplane method (difference -0.036) and maximum for 3DE method (-0.098) . Difference of each method with PHT showed lowest difference with 3D Xplane (-0.30) and highest with 3DE (-0.63). Conclusions: TTE 3D Xplane provides accurate and highly reproducible measurements of MVA and can easily be performed from optimal PLAX view and corresponding parasternal short-axis views acquired in the same bisected image using 3D Xplane technique . It was much easier and faster to defne the image plane in short axis with the smallest orifce area when 3D Xplane method was used.
Authors and Affiliations
Amit Kumar Agarwal| National Academy of Medical Sciences, Kathmandu, Deewakar Sharma| Shahid Gangalal National Heart Centre, Bansbari, Kathmandu, Sajan Gopal Baidya| Shahid Gangalal National Heart Centre, Bansbari, Kathmandu, Dipanker Prajapati| Shahid Gangalal National Heart Centre, Bansbari, Kathmandu
Fast-Track Cardiac Anaesthesia at a Tertiary Care Cardiac Centre in Nepal
Background: With the evolution of anesthesia and surgical procedures, fast track cardiac anaesthesia has gained an increased interest, mainly based on the possibility of reducing health costs without compromising patient...
Variability among 2D and 3D methods of calculating mitral valve area: a comparative study with pressure half time method
Background and Aims: The aim of this study was to evaluate the feasibility, reproducibility and accuracy of Live Three dimensional Echocardiography (3DE), Two dimensional Echocardiography (2DE) and Three dimensional Xp...
Rheumatic Fever and Antibody Response to Group A Streptococcal Infections
Rheumatic fever is non-suppurative sequel of group A streptococcal infection. It is a multifocal inflammatory disease, affecting primarily the heart, joints, skin and central nervous system occurring in 0.1% to 3% after...
Allergic reacton to long – term Benzathine penicillin injecton for secondary preventon of acute rheumatc fever and recommendatons for skin testng
Background Rheumatc Fever (RF) causes 25-40% of all cardio vascular disease in developing countries. Long term benzathine penicillin injecton is being used for secondary prophylaxis of RF / RHD. Although allergic react...
Safety and Diagnostic Accuracy of Dobutamine Stress Echocardiography
Exercise and pharmacologic stress echocardiography has been used routinely in clinical practice for the past twenty to thirty years. Dobutamine stress echocardiography (DSE) is well established as a safe, feasible, and...