Визначення необхідної потужності електричних теплоакумуляційних обігрівачів

Abstract

The article analyzes the methods proposed for selection of storage heaters. Generally, these methods determine the required power inputs for storage heaters depending on the period of cheap pick-off electricity tariff, space parameters (heat loss, purpose, thermal characteristics, etc.) and a chosen type of storage heater. Most of the analyzed methods determine the power input for only one type of storage heaters. The required power input is calculated by multiplying heat loss and a correlation factor. The typical power inputs of storage heaters are shown depending on their heat transfer type and a placement of heaters. In modern devices, unlike previous ones, additional heating elements are placed in a front panel to ensure greater reliability of devices and for maintaining accurate control of room temperature. Also, power inputs of modern storage heaters have decreased compared to previous ones. That can be explained by a corresponding reduction in the allowable values of heat loss in modern buildings. The analysis showed the discrepancy between calculation methodologies in terms of calculating power inputs for storage heaters.

Authors and Affiliations

O. Lysak

Keywords

Related Articles

ANALYSIS OF INFLUENCE OF MAIN TYPES OF DEFECTS AND DAMAGE ON THE BEARING CAPASITY OF REINFORCED CONCRETE ELEMENTS

In nowadays economic trends, there is a need in changes in the usage of buildings and structures. This usually leads to the changes loading and character of the loadings type on the building structures, with the subseque...

Двокамерні повітророзподільники

The current state and trends of air displacement ventilation systems for public and industrial buildings are analyzed. It identified the significant advantages of displacement ventilation.. Disadvantages of the existing...

MODELLING OF REINFORCED CONCRETE BEAMS WITH PRETENSIONED FRP REINFORCEMENT

Traditional building materials are regularly improved, finding new operational characteristics and complementing the quality of technical parameters. For a long time and now as reinforcement of reinforced concrete elemen...

Дослідження процесу остигання будівлі в умовах припинення теплопостачання

The article presents the theoretical calculations and the experimental research time cooling of the building in terms of existing heating systems during the cold season while to using periodic mode of heating, which is o...

ДЕФОРМАТИВНІСТЬ ВУЗЛІВ ДЕРЕВ’ЯНИХ КОНСТРУКЦІЙ НА З’ЄДНАННЯХ ТИПУ “СТАЛЬ-ДЕРЕВИНА”

Nowadays design of timber buildings and constructions growth up. It is connected with the dissemination of eco-technologies, efficient energy-saving buildings, rapid constructing, inexpensive solutions and addicting to s...

Download PDF file
  • EP ID EP230887
  • DOI -
  • Views 85
  • Downloads 0

How To Cite

O. Lysak (2016). Визначення необхідної потужності електричних теплоакумуляційних обігрівачів. Вісник Національного університету "Львівська політехніка". Серія "Теорія та практика будівництва", 0(844), 127-138. https://europub.co.uk/articles/-A-230887