Визначення необхідної потужності електричних теплоакумуляційних обігрівачів

Abstract

The article analyzes the methods proposed for selection of storage heaters. Generally, these methods determine the required power inputs for storage heaters depending on the period of cheap pick-off electricity tariff, space parameters (heat loss, purpose, thermal characteristics, etc.) and a chosen type of storage heater. Most of the analyzed methods determine the power input for only one type of storage heaters. The required power input is calculated by multiplying heat loss and a correlation factor. The typical power inputs of storage heaters are shown depending on their heat transfer type and a placement of heaters. In modern devices, unlike previous ones, additional heating elements are placed in a front panel to ensure greater reliability of devices and for maintaining accurate control of room temperature. Also, power inputs of modern storage heaters have decreased compared to previous ones. That can be explained by a corresponding reduction in the allowable values of heat loss in modern buildings. The analysis showed the discrepancy between calculation methodologies in terms of calculating power inputs for storage heaters.

Authors and Affiliations

O. Lysak

Keywords

Related Articles

Comparison of efficient of the combined solar collector for energy-efficient buildings for different modes of operation

On the whole, alternative energy should contribute to taking the two pressing problems of environmental safety and energy efficiency. Solar energy, as energy resources of the future, has a lot of benefits. It is mainly h...

Monitoring of indoor air in the apartment

Apartment occupants have a major impact on indoor air quality. Indoor air pollution includes water vapour, carbon dioxide and other gases due to respiration and bodily odours. Negative impact they have from brought in by...

THEORETICAL ANALYSIS OF BUILDING INFORMATION MODELING LIBRARIES (BIML)

The main countries benefiting from BIM support are countries like Finland, Norway, Denmark, Great Britain and USA. One of the support from BIM are Building Information Modeling Library (BIML). This paper presents the dev...

THE METHODOLOGY AND RESULTS OF EXPERIMENTAL INVESTIGATIONS OF STEEL AND CONCRETE COMPOSITE CABLE SPACE FRAME ON EFFECT SHORT-TERM LOADING

and concrete composite cable space frame 5.3 m on effect short-term loading. The experimental sample consisted of flexible elements of the lower belt and steel and concrete composite space modules. Elements of the lower...

Аналіз систем утеплення будівель з врахуванням життєвого циклу теплової ізоляції

Each increase of energy tariffs actualizes the problem of insulation of buildings in order to reduce heating costs. This raises the question of choice of insulating material. In the article is considered the actual quest...

Download PDF file
  • EP ID EP230887
  • DOI -
  • Views 71
  • Downloads 0

How To Cite

O. Lysak (2016). Визначення необхідної потужності електричних теплоакумуляційних обігрівачів. Вісник Національного університету "Львівська політехніка". Серія "Теорія та практика будівництва", 0(844), 127-138. https://europub.co.uk/articles/-A-230887