Wear of the Implant Connection with Zirconia and Titanium Abutments

Journal Title: Open Access Journal of Dental Sciences - Year 2017, Vol 2, Issue 6

Abstract

1.1. Background: Classify and quantify the wear of the implant and abutment interface simulating a loose screw situation. 1.2. Methods: Nine external connection titanium implants were split into 4 groups: Group A (no hexagon titanium abutment), Group B Titanium abutment (with hexagon) (n=3), Group C Zirconia abutment with hexagon (n=3) and Group D mix abutments (n=2). All components were individually weighted and the rotational freedom for each pair was access before and after testing. The specimens were tested an Instron 8874 fitted with a dynamic load cell with a torque capacity of 100Nm and a precision of 0.5% from 1% of the full scale. They were loaded with a sinusoidal rotational angle that was different for each group (A= 6º, B= 3.3º, C= 0.835º, D=6.6 º), 4 Hz, for 250.000 cycles. After testing all components were photographed with a SEM. Spearman’s correlation analysis was made. 1.3. Results: Regardless of angle and materials the rotational freedom increased in all groups. Volume loss with zirconia abutment was more than double than with a titanium abutment. 1.4. Conclusion: The loose screw in implant prosthesis may lead to the wear of the hexagon on both components. This wear is sufficient to compromise the connection beyond repair.

Authors and Affiliations

José Alexandre Reis

Keywords

Related Articles

Indirect Bonding in Lingual Orthodontics

Indirect bonding of lingual brackets is crucial to the success of lingual orthodontic treatment. Transferring brackets to the pre determined position in a precise manner to patients’ mouth is of paramount importance. Thi...

Pattern of Mandibular Third Molar Impaction and Relationship to the Inferior Alveolar Canal: Retrospective Cone Beam Computed Tomography Analysis in a Group of Sri Lankan Patients

Cone beam computed tomography (CBCT) provides a precise three dimensional analysis of vicinity of Impacted Mandibular third molar (IMTM) which helps in surgical decision making. Objective: Objective of this study was to...

Ergonomics: Important Aspect for Dental Students

Recent socio-economic changes (stiffer competition, more demanding patients, more intensive working conditions) have made the daily work of the dentist increasingly stressful. Excessive mental pressures have given rise t...

Autologus Barriers, Fillers and Growing Factors: Using the Secondary Pathway of Haemostasis in Dental Clinics-Report of Four Clinical Cases

Haemostasis is an important system that maintain the hydrolytic balance of the body. The secondary pathway of this system produce a fibrin network to improve coagulation and regeneration. Platelet rich in fibrin, use the...

Treatment of Acute Apical Abscess in Diabetic Patient by Single Visit Endodontics- A Case Report

The aim of the case report is to describe the effectiveness and success of single visit endodontics in apical abscess in patient suffering from diabetes. Infected non vital tooth was treated with single visit endodontic...

Download PDF file
  • EP ID EP290709
  • DOI -
  • Views 111
  • Downloads 0

How To Cite

José Alexandre Reis (2017). Wear of the Implant Connection with Zirconia and Titanium Abutments. Open Access Journal of Dental Sciences, 2(6), 1-9. https://europub.co.uk/articles/-A-290709