Wind interference effect on an octagonal plan shaped tall building due to square plan shaped tall buildings

Journal Title: International journal of advanced structural engineering - Year 2016, Vol 8, Issue 1

Abstract

The variation of pressure at the faces of the octagonal plan shaped tall building due to interference of three square plan shaped tall building of same height is analysed by computational fluid dynamics module, namely ANSYS CFX for 0 wind incidence angle only. All the buildings are closely spaced (distance between two buildings varies from 0.4h to 2h, where h is the height of the building). Different cases depending upon the various positions of the square plan shaped buildings are analysed and compared with the octagonal plan shaped building in isolated condition. The comparison is presented in the form of interference factors (IF) and IF contours. Abnormal pressure distribution is observed in some cases. Shielding and channelling effect on the octagonal plan shaped building due to the presence of the interfering buildings are also noted. In the interfering condition the pressure distribution at the faces of the octagonal plan shaped building is not predictable. As the distance between the principal octagonal plan shaped building and the third square plan shaped interfering building increases the behaviour of faces becomes more systematic. The coefficient of pressure (Cp) for each face of the octagonal plan shaped building in each interfering case can be easily found if we multiply the IF with the Cp in the isolated case.

Authors and Affiliations

Rony Kar, Sujit Kumar Dalui

Keywords

Related Articles

Investigation of the nonlinear seismic behavior of knee braced frames using the incremental dynamic analysis method

In knee braced frames, the braces are attached to the knee element rather than the intersection of beams and columns. This bracing system is widely used and preferred over the other commonly used systems for reasons such...

A new method to assess damage to RCMRFs from period elongation and Park–Ang damage index using IDA

Despite a significant progress in loading and design codes of seismic resistant structures and technology improvements in building structures, the field of civil engineering is still facing critical challenges. An exampl...

Scaled accelerographs for design of structures in Quetta, Baluchistan, Pakistan

Structural design for seismic excitation is usually based on peak values of forces and deformations over the duration of earthquake. In determining these peak values dynamic analysis is donewhich requires either response...

Inelastic deformation demands of regular steel frames subjected to pulse-like near-fault ground shakings

Evaluating the capability of elastic Load Patterns (LPs) including seismic codes and modified LPs such as Method of Modal Combination (MMC) and Upper Bound Pushover Analysis (UBPA) in estimating inelastic demands of non...

Seismic response of an elevated aqueduct considering hydrodynamic and soil-structure interactions

In conventional design of an elevated aqueduct, apart from considering the weight of water inside the channels, hydrodynamic forces are generally neglected. In a few special cases involving high seismic zones, hydrodynam...

Download PDF file
  • EP ID EP210408
  • DOI 10.1007/s40091-016-0115-z
  • Views 117
  • Downloads 0

How To Cite

Rony Kar, Sujit Kumar Dalui (2016). Wind interference effect on an octagonal plan shaped tall building due to square plan shaped tall buildings. International journal of advanced structural engineering, 8(1), 73-86. https://europub.co.uk/articles/-A-210408