Wind interference effect on an octagonal plan shaped tall building due to square plan shaped tall buildings

Journal Title: International journal of advanced structural engineering - Year 2016, Vol 8, Issue 1

Abstract

The variation of pressure at the faces of the octagonal plan shaped tall building due to interference of three square plan shaped tall building of same height is analysed by computational fluid dynamics module, namely ANSYS CFX for 0 wind incidence angle only. All the buildings are closely spaced (distance between two buildings varies from 0.4h to 2h, where h is the height of the building). Different cases depending upon the various positions of the square plan shaped buildings are analysed and compared with the octagonal plan shaped building in isolated condition. The comparison is presented in the form of interference factors (IF) and IF contours. Abnormal pressure distribution is observed in some cases. Shielding and channelling effect on the octagonal plan shaped building due to the presence of the interfering buildings are also noted. In the interfering condition the pressure distribution at the faces of the octagonal plan shaped building is not predictable. As the distance between the principal octagonal plan shaped building and the third square plan shaped interfering building increases the behaviour of faces becomes more systematic. The coefficient of pressure (Cp) for each face of the octagonal plan shaped building in each interfering case can be easily found if we multiply the IF with the Cp in the isolated case.

Authors and Affiliations

Rony Kar, Sujit Kumar Dalui

Keywords

Related Articles

Investigation of the nonlinear seismic behavior of knee braced frames using the incremental dynamic analysis method

In knee braced frames, the braces are attached to the knee element rather than the intersection of beams and columns. This bracing system is widely used and preferred over the other commonly used systems for reasons such...

Optimal placement of active braces by using PSO algorithm in near- and far-field earthquakes

One of the most important issues in tall buildings is lateral resistance of the load-bearing systems against applied loads such as earthquake, wind and blast. Dual systems comprising core wall systems (single or multi-ce...

Cyclic performance of concrete-filled steel batten built-up columns

Steel built-up batten columns are common types of columns in Iran and some other parts of the world. They are economic and have acceptable performance due to gravity loads. Although several researches have been conducted...

The effect of multi-directional nanocomposite materials on the vibrational response of thick shell panels with finite length and rested on two-parameter elastic foundations

The main purpose of this paper is to investigate the effect of bidirectional continuously graded nanocomposite materials on free vibration of thick shell panels rested on elastic foundations. The elastic foundation is co...

NDT evaluation of long-term bond durability of CFRP-structural systems applied to RC highway bridges

The long-term durability of CFRP structural systems applied to reinforced-concrete (RC) highway bridges is a function of the system bond behavior over time. The sustained structural load performance of strengthened bridg...

Download PDF file
  • EP ID EP210408
  • DOI 10.1007/s40091-016-0115-z
  • Views 118
  • Downloads 0

How To Cite

Rony Kar, Sujit Kumar Dalui (2016). Wind interference effect on an octagonal plan shaped tall building due to square plan shaped tall buildings. International journal of advanced structural engineering, 8(1), 73-86. https://europub.co.uk/articles/-A-210408