ZAHN-WELLENS TEST IN INDUSTRIAL WASTEWATER BIODEGRADABILITY ASSESSMENT

Journal Title: Civil and Environmental Engineering Reports - Year 2018, Vol 1, Issue 28

Abstract

Biodegradability of pollution contained in examined industrial wastewater was assessed according to methodology based on Zahn-Wellens (OECD 302B) test. The following kinds of wastewater were examined: - metal industry wastewater from aluminium pressure foundry; - wastewater from industrial waste treatment processes, such as: filtration waste, chemical reagents, coolants, water emulsions, oil wastes and other industrial wastes, galvanising waste treatment processes sludge. Samples COD value decrease in the subsequent days of the experiment proves that organic substances contained in the examined wastewater undergo gradual biodegradability in aerobic conditions. The highest biodegradability degree of aluminium pressure foundry wastewater equal 65.7% was noted during 28 day of the experiment. However, the minimum biodegradability degree equal 80% after 13 aeration days, which in Zahn-Wellens test allows to determine the examined substance to be biodegradable, has not been achieved. Meanwhile, Zahn-Wellens test conducted for wastewater from industrial waste treatment processes showed that in the day 14 of the process, high (87.1%) organic substance degradation degree, measured with COD value decrease, was achieved. Further aeration of the samples did not increase biodegradability, which equalled 87.9% after 28 days.<br/><br/>

Authors and Affiliations

Ewelina PŁUCIENNIK-KOROPCZUK, Sylwia MYSZOGRAJ

Keywords

Related Articles

CYLINDRICAL SHELLS MADE OF STAINLESS STEEL – INVESTIGATION OF POSTBUCKLING

The relevant load case of open thin-walled shells is often wind loading during construction. Because of the missing stabilization effect of the roof they show a very high sensitivity to buckling which results into higher...

EQUIVALENT STABILIZING FORCE OF THE SIMPLY SUPPORTED ROOF GIRDERS INCLUDING THE LONGITUDINAL VARIABILITY OF THE COMPRESSION FORCE ACTING IN THE RESTRAINED CHORD

In the calculation model of the equivalent stabilizing force qd for bracing system consistent with EN 1993-1-1 it has been conservatively assumed that the member to be restrained is uniformly compressed within its length...

Technical and economic aspects of industrial laundry wastewater treatment

Three biological methods of laundry wastewater purification were tested, in pilot scale, in Fliegel Textilservice laundry in Nowe Czarnowo. Among tested methods, rotating biological contactor, membrane bioreactor and spo...

NATURAL GAS SAVING AND EMISSIONS DECREASE IN PUBLIC HEALTH CARE SECTOR – A CASE STUDY

A study on natural gas saving and emissions decrease in the public health care sector is presented. The analyzed hospital complex belongs to the largest ones in Slovakia and uses both hot water and water steam for heatin...

Download PDF file
  • EP ID EP346027
  • DOI 10.2478/ceer-2018-0007
  • Views 68
  • Downloads 0

How To Cite

Ewelina PŁUCIENNIK-KOROPCZUK, Sylwia MYSZOGRAJ (2018). ZAHN-WELLENS TEST IN INDUSTRIAL WASTEWATER BIODEGRADABILITY ASSESSMENT. Civil and Environmental Engineering Reports, 1(28), 77-86. https://europub.co.uk/articles/-A-346027