A contiguous ramp and all-out exercise test to determine critical power in competitive cyclists

Journal Title: Journal of Science and Cycling - Year 2014, Vol 3, Issue 2

Abstract

Background: Critical power (CP) represents the highest metabolic rate at which oxygen uptake and blood lactate stabilizes during exercise and is strongly associated with endurance exercise performance. Determination of CP typically requires the completion of two to five constant power tests to exhaustion (TTE). An alternative test involves measurement of mean power during the final 30 s of a single 3-minute all-out cycling test, and this test agrees well with CP (Vanhatalo et al.,2007: Medicine and Science in Sports and Exercise, 39, 548-555). However, the 3-minute all-out test requires a preliminary Ramp test to determine the ergometer settings for the subsequent CP assessment. Purpose: To quantify the reliability of a single contiguous Ramp and 3-minute All-Out test (RAO), and to appraise validity relative to CP determined from serial TTE tests. Methods: All participants provided written informed consent prior to participation, tests were separated by 2 – 7 d, and studies by 6 – 12 months. Reliability study: Four male triathletes, six male and one female road cyclist ( 2peak 4.32 ± 0.70 L•min-1) completed two RAO (RAO 1 & 2) cycle ergometer tests (Lode Excalibur Sport, Groningen, The Netherlands). The RAO was a contiguous 5-min warm up at 50 W, a ramp-incremental (30 W•min-1) to exhaustion, and a 3-min all-out exercise test. Exhaustion was defined as a cadence ≤ 50 rpm. The ergometer resistance during the AO phase was defined prior to exercise using: (body mass (kg) x 3.5) / 852. Cadence and duration was withheld during the AO phase. Validity study: Five triathletes and two road cyclists ( 2peak 3.96 ± 0.53 L•min-1) completed the RAO before and after a series of at least four constant power TTE designed to elicit exhaustion between ~ 3-15 min. For TTE tests the asymptote (CP) and curvature constant (W´) of the power-duration relationship were quantified using 2-parameter nonlinear regression models. For RAO tests the estimated CP (ECP) was calculated as the mean power output over the final 30 s of the RAO, and estimated W´ (EW´) was calculated as the power-time integral above ECP during the RAO. Statistics: Data are reported as mean, standard deviation. Data was appraised using a repeated measures general linear model for quantification of bias and typical error (TE). The relationship between protocols was quantified using coefficient of variation (CV). Results: Reliability study: ECP in RAO1 (289, 38 W) and RAO2 (292, 41 W) were not different (P = 0.24, TE 7 W, mean bias of 4 ± 19 W). ECP between repeats were very strongly related (CV 2%). EW´ in RAO1 (12.6, 3.4 kJ) and RAO2 (12.0, 4.2 kJ) were not different (P = 0.49, TE 2.0 kJ, mean bias of -0.6 ± 5.5 kJ), and were related (CV 13%). Validity study: Durations of TTE ranged from 170 (34) to 861 (202) s. A 5 W (1.8%) standard error was associated with the estimate of CP using the 2-parameter model. ECP (280, 36 W) was not different to CP (279, 34 W; P = 0.95, TE 10 W). Comparisons revealed a mean bias of 1 ± 27 W, (CV 3%). EW´ (17.1, 3.4 kJ) was not different to W´ (15.8, 2.8 kJ; P = 0.461, TE 1.8 kJ, mean bias of -1.35 ± 8.9 kJ), EW´ and W´ were related (CV 14%). Discussion: The RAO test parameters were sufficiently reliable for use in future studies. Similar to previous studies investigating alternative methods for power-duration curve estimation, the reproducibility of ECP was small (CV 2%), but EW´ was wider (13%). The mean difference between parameter estimates of CP and W´ using the traditional TTE test and single RAO test was negligible. The limits of agreement between the CP estimate derived from a series of maximal constant power TTE tests and the single test RAO protocol were moderately wide (27 W) but similar to previous reports of AO-exercise strategies for CP estimation. Conclusion: The CP and W´ estimates from a single test were similar to traditional testing methods that require multiple maximal exercise tests. Therefore, the RAO test may simplify CP estimation in competitive cyclists.

Authors and Affiliations

MS Wells| Sport and Exercise Sciences, Liverpool Hope University, United kingdom, G Atkinson| Health and Social Care Institute, Teesside University, United kingdom, HB Rossiter| Los Angeles Biomedical Research Institute at Harbor-UCLA Medical Center, U.S.A., S Marwood| Sport and Exercise Sciences, Liverpool Hope University, United kingdom

Keywords

Related Articles

Validity of Track Aero System to assess aerodynamic drag in professional cyclists

Purpose: Aerodynamic drag is the main resistance (80-90 %) among the total resistive forces (RT, N) opposing motion on level ground in cycling. It is important to decrease it to improve the performance in time-trial (TT)...

Increased physical effort overrides the potentially deleterious effects of resource depletion following self-control

Background: Long duration cycling events require riders to maintain concentration and self-control over lengthy periods, for example, listening to race plans and/or eve-dropping on conversations of other riders whilst...

Internal Mechanical Power During Cycling Using Non-Circular Versus Circular Chainrings

Introduction: Non-circular Rotor Q-Rings have been shown to increase tangential force during the pedalling downstroke compared to conventional circular chainrings1, and due to this advantage, have been proposed as a pote...

The reliability of a 30-minute performance test on a Lode cycle ergometer

High retest reliability is desirable in tests used to monitor athletic performance. The purpose of the present study was to determine the reliability of a 30-minute cycle test on a cycle ergometer (Lode, Groningen, Nethe...

Assessment of Serum 25 (OH) Vitamin D Status in Elite Portuguese Cycling Athletes

It is recognized that vitamin D has multiple effects in health (Autier, Boniol et al. 2014) and in athletic performance (Ogan and Pritchett 2013). It has been shown that it may have a role in the immune function, protein...

Download PDF file
  • EP ID EP2883
  • DOI -
  • Views 418
  • Downloads 27

How To Cite

MS Wells, G Atkinson, HB Rossiter, S Marwood (2014). A contiguous ramp and all-out exercise test to determine critical power in competitive cyclists. Journal of Science and Cycling, 3(2), 0-0. https://europub.co.uk/articles/-A-2883