A PCA/ICA based Fetal ECG Extraction from Mother Abdominal Recordings by Means of a Novel Data-driven Approach to Fetal ECG Quality Assessment

Journal Title: Journal of Biomedical Physics and Engineering - Year 2017, Vol 7, Issue 1

Abstract

Background: Fetal electrocardiography is a developing field that provides valuable information on the fetal health during pregnancy. By early diagnosis and treatment of fetal heart problems, more survival chance is given to the infant. Objective: Here, we extract fetal ECG from maternal abdominal recordings and detect R-peaks in order to recognize fetal heart rate. On the next step, we find a better and more qualified extracted fetal ECG by using a novel approach. Method: In this paper, a PCA/ICA-based algorithm is proposed for extracting fetal ECG, and fetal R-peaks are detected as well. The method validates the quality of extracted ECGs and selects the best candidate fetal ECG to provide the required morphological ECG features such as fetal heart rate and RR interval for more clinical examinations. The method was evaluated using the dataset which was provided by PhysioNet/Computing in Cardiology Challenge 2013. The dataset consists of 75 recordings of 4-channel ECGs each containing 1-minute length for training and 100 similar recordings for testing. Results: When the proposed algorithm was applied to the test set, the scores of 85.853 bpm2 for fetal heart rate and an error of 9.725 ms RMS for fetal RR-interval estimation were obtained. Conclusion: The results obtained with the mentioned algorithm shows the robustness of the research, and it is suggested to be used in practical fetal ECG monitoring systems.

Authors and Affiliations

A Karimi Rahmati, S K Setarehdan, B N Araabi

Keywords

Related Articles

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support...

A Monte Carlo Study on the Effect of Various Neutron Capturers on Dose Distribution in Brachytherapy with 252Cf Source

Background: In neutron interaction with matter and reduction of neutron energy due to multiple scatterings to the thermal energy range, increasing the probability of thermal neutron capture by neutron captures makes dose...

Melatonin Role in Ameliorating Radiation-induced Skin Damage: From Theory to Practice (A Review of Literature)

Normal skin is composed of epidermis and dermis. Skin is susceptible to radiation damage because it is a continuously renewing organ containing rapidly proliferating mature cells. Radiation burn is a damage to the skin o...

Evaluation of Blood Parameters Alteration Following Low-dose Radiation Induced by Myocardial Perfusion Imaging

Introduction: With increasing the usage of myocardial perfusion imaging (MPI) for the diagnosis of ischemic heart disease, we aimed to evaluate the side effects of low-dose radiation induced by this technique on blood el...

Download PDF file
  • EP ID EP330210
  • DOI -
  • Views 116
  • Downloads 0

How To Cite

A Karimi Rahmati, S K Setarehdan, B N Araabi (2017). A PCA/ICA based Fetal ECG Extraction from Mother Abdominal Recordings by Means of a Novel Data-driven Approach to Fetal ECG Quality Assessment. Journal of Biomedical Physics and Engineering, 7(1), 37-50. https://europub.co.uk/articles/-A-330210