Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

Journal Title: Journal of Biomedical Physics and Engineering - Year 2019, Vol 9, Issue 4

Abstract

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of artificial heart transplantation. In this work, a new equivalent Left Ventricular Assist Device (LVAD) is designed and implemented as a simple circuit for medical equipment labs. The presented LVDA consists of a mechanical motor, tubes, a power source, and microcontroller. The output results show the range of readings near the percentage ranges of the left ventricular pumping of the human adult. This work is significant for the biomedical equipment’s lab. The researcher can deal with the function of the important medical devices which are artificial that can record different readings. Citation: Nazeeh N. N, Aljobouri H. K, Odai M. Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs. J Biomed Phys Eng. 2019;9(4):495-500. https://doi.org/10.31661/jbpe.v0i0.1171.

Authors and Affiliations

H. K. Aljobouri, N. N. Nazeeh, M. Odai

Keywords

Related Articles

Manipulation Effect on Lumbar Kinematics in Patients with Unilateral Innominate Rotation and Comparison with Asymptomatic Subjects

Background: Lumbar motion analysis is used as a clinical method in the diagnosis and treatment of low back pain (LBP). So far, no studies have shown if manipulating the sacroiliac joint (SIJ) will change spinal kinematic...

Beam Collimation during Lumbar Spine Radiography: A Retrospective Study

Introduction: Collimating the primary beam to the area of diagnostic interest (ADI) has been strongly recommended as an effective method to reduce patient’s radiation dose and to improve image quality during radiology pr...

Radiation-induced Non-targeted Effect and Carcinogenesis; Implications in Clinical Radiotherapy

Bystander or non-targeted effect is known to be an interesting phenomenon in radiobiology. The genetic consequences of bystander effect on non-irradiated cells have shown that this phenomenon can be considered as one of...

A Framework for Optimal Attribute Evaluation and Selection in Hesitant Fuzzy Environment Based on Enhanced Ordered Weighted Entropy Approach for Medical Dataset

Background: In this paper, a generic hesitant fuzzy set (HFS) model for clustering various ECG beats according to weights of attributes is proposed. A comprehensive review of the electrocardiogram signal classification a...

The Influence of Brass Compensator Thickness and Field Size on Neutron Contamination Spectrum in 18MV Elekta SL 75/25 Medical Linear Accelerator with and without Flattening Filter: A Monte Carlo Study

Background: One of the most significant Intensity Modulated Radiation Therapy treatment benefits is a high target to normal tissue dose ratio. To improve this advantage, an additional accessory such as a compensator is u...

Download PDF file
  • EP ID EP648063
  • DOI -
  • Views 99
  • Downloads 0

How To Cite

H. K. Aljobouri, N. N. Nazeeh, M. Odai (2019). Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs. Journal of Biomedical Physics and Engineering, 9(4), 495-500. https://europub.co.uk/articles/-A-648063