A PREDICTIVE CONTROL ALGORITHM FOR AN ACTIVE THREE-PHASE POWER FILTER
Journal Title: Електротехніка і Електромеханіка - Year 2014, Vol 0, Issue 4
Abstract
The paper deals with grid connection circuits for active filters, structures of active power filter control systems, and methods based on full capacity components determination. The existing structures of active power filter control and control algorithm adjustment for valve commutation loss reduction are analyzed. A predictive control algorithm for an active three-phase power filter is introduced.
Authors and Affiliations
R. V. Vlasenko, O. V. Bialobrzeski
DIRECT FREQUENCY CONVERTER WITH ARTIFICIAL AND NATURAL COMMUTATION FOR BRUSHLESS ASYNCHRONIZED MACHINES
The comparative analysis of direct frequency converters with artificial and natural- switching term of the cyclical control algorithm is presented; the recommendations for their using in brushless asynchronized machines...
NETWORK-CENTRIC TECHNOLOGIES FOR CONTROL OF THREE-PHASE NETWORK OPERATION MODES
Purpose. The development of the control system for three-phase network is based on intelligent technologies of network-centric control of heterogeneous objects. The introduction of unmanned aerial vehicles for monitoring...
PECULIARITIES OF CALCULATION OF MAGNETIC SYSTEMS WITH SHORT-CIRCUITED SECONDARY WINDINGS IN IN-PLANE FORMULATION
Introduction. A feature of quasi-static calculation of plane electromagnetic fields is unlimited volume occupied by the current. This condition imposes certain requirements on the choice of boundary conditions for solvin...
OBJECTIVE FUNCTIONS OF THE COMPARATIVE ANALYSIS OF THE ENERGY EFFICIENCY OF ELECTROMAGNETIC SYSTEMS OF INDUCTION MOTORS WITH INNER AND OUTER ROTORS
The analytical expressions of determining the optimum geometric dimensions by criteria of the basic losses minimum of the structural variants of the electromagnetic system of the induction squirrel-cage motor with inner...
RELAXATIONS LOSSES IN POLYETHYLENE INSULATION OF COAXIAL CABLE STRUCTURE DURING AGING IN HIGH HUMIDITY CONDITIONS
Introduction. The presence of free moisture in power cables leading to the formation of tree structures - water treeing, which originate in the amorphous phase polyethylene and are a major cause of degradation of the pol...