A Simplified Approach for Prosthetic Rehabilitation of an Anophtalmic Patient with Chronic Mucoid Discharge Using a Previous Ocular Prosthesis

Journal Title: Journal of Research in Medical and Dental Science - Year 2017, Vol 5, Issue 5

Abstract

The defects of eye, whatever the cause, are associated with significant anatomical deficiency and emotional and psychological disturbance for affected patients. Defect size may range from a small enucleation defect to an extensive exenterated one affecting eye and surrounding soft and hard tissues in maxillofacial complex. A properly fabricated custom ocular or orbital prosthesis could give the patient an optimal normalcy in social and psychological as well as functional aspects. A 68-year-old male patient presented with an enucleation defect in the left eye. After clinical examination, an impression was taken with additional silicon elastomeric impression material using patient’s previous prosthesis as a custom tray. Then, the scleral blank was made from wax and the Iris was attached to it. The external clear acrylic resin was packed and processed. The prosthesis was polished and delivered to patient. Modifying and converting a previously fabricated ocular prosthesis into a newly fabricated well-fitting custom ocular prosthesis can help minimizing clinical adjustments and simplifying laboratory procedures.

Authors and Affiliations

Memari Y, Fayaz A, Tadayonfard A

Keywords

Related Articles

Determination of titanium in orthodontic with modified graphene paste electrode and ionic liquid by potentiometric method

Two new potentiometric methods for determination of titanium in pure form and in its pharmaceutical form are developed. In the first method, new modified carbon paste electrode based on(SAPD) as a chemical modifier. The...

Attitudes and Interests of Students in Different Disciplines in Islamic Azad University, Tehran, Medical Sciences Branch to Their Field of Study at the Entrance to University

Having interest and a positive attitude towards field of study is one of the requirements in learning and achieving success. Despite the time, cost and effort in choosing the discipline, a number of students change their...

Evaluating the association between first trimester screening tests and adverse perinatal outcomes

Prenatal screening tests are not diagnostic and only show and determine the risk of fetal abnormalities. This study aimed to evaluate the association between the results of double marker test and nuchal translucency (NT)...

Predictor Factors that Influence the Results of Sudden Deafness Therapy

Sudden deafness is an emergency case in otorhinolaryngology (ORL). Standard therapy did not result in the same hearing improvement between cases. There are some factors that may influence the therapeutic result therefore...

Measurement of doxycycline in pharmaceutical Samples with SnO2 nanoparticles by spectrophotometric method

In this work, The SnO2 nanoparticles were characterized which developed a novel SnO2 nanoparticleassisted matrix solid-phase extraction (SnO2 -SPE) method for extraction of doxycycline from pharmaceutical and environment...

Download PDF file
  • EP ID EP326265
  • DOI -
  • Views 214
  • Downloads 0

How To Cite

Memari Y, Fayaz A, Tadayonfard A (2017). A Simplified Approach for Prosthetic Rehabilitation of an Anophtalmic Patient with Chronic Mucoid Discharge Using a Previous Ocular Prosthesis. Journal of Research in Medical and Dental Science, 5(5), 61-65. https://europub.co.uk/articles/-A-326265