A Study of K- Factor Power Transformer Characteristics by Modeling Simulation

Journal Title: Engineering, Technology & Applied Science Research - Year 2011, Vol 1, Issue 5

Abstract

Harmonic currents generated by nonlinear loads can cause overheating and premature failure in power transformers. K-factor transformers are specially designed to accommodate harmonic currents and offer protection against overheating caused by harmonics. They minimize harmonic current loss and have an additional thermal capacity of known limits. According to IEEE C57-110, the winding eddy current losses are considered proportional to the harmonic current squared times its harmonic number. K-factor is only an indicative value and the authors' main objective in this paper is to study the effect of harmonics on oil filled transformer and to simulate harmonic behavior using Matlab Simulink. A case study is simulated in order to investigate K-factor values with pumping loads, with and without the use of harmonic filters. Results are compared with measured values.

Authors and Affiliations

O. E. Gouda, G. M. Amer, W. A. A. Salem

Keywords

Related Articles

Analysis of a Frame-Shear Wall Concrete Structure by Using Base Isolation and Evaluation of Structure-Soil Interaction

A base isolation system is a type of earthquake-resistant structure design approach based on the principle of reducing a structure’s earthquake response rather than increasing the structure’s earthquake resistance capaci...

Motivation Factors for Adopting Building Information Modeling (BIM) in Iraq

Building information modeling (BIM) is an integrated and comprehensive system including whatever is related to a construction project and its stages. It represents a unified database for all project data through which pr...

Enhancing Transient Stability in Limited Variable Speed Induction Generator (Optislip) Based Wind Turbine (Case study: Binalood Wind Farm)

Enormous penetration of wind power in power systems and its contribution in covering a major part of grid load demand, require higher stability during disturbances. The most important issue of wind generators is the earl...

Secure Data Encryption Through a Combination of AES, RSA and HMAC

Secure file transfer based upon well-designed file encryption and authorization systems expend considerable effort to protect passwords and other credentials from being stolen. Transferring and storing passwords in plain...

Quality Analysis of Urea Plant Wastewater and its Impact on Surface Water Bodies

This study was conducted on the canal water that flows besides an urea manufacturing facility. The study focused to evaluate the impact of facility’s effluents. The canal water quality is being affected drastically due t...

Download PDF file
  • EP ID EP84802
  • DOI -
  • Views 262
  • Downloads 0

How To Cite

O. E. Gouda, G. M. Amer, W. A. A. Salem (2011). A Study of K- Factor Power Transformer Characteristics by Modeling Simulation. Engineering, Technology & Applied Science Research, 1(5), -. https://europub.co.uk/articles/-A-84802