A Study of K- Factor Power Transformer Characteristics by Modeling Simulation

Journal Title: Engineering, Technology & Applied Science Research - Year 2011, Vol 1, Issue 5

Abstract

Harmonic currents generated by nonlinear loads can cause overheating and premature failure in power transformers. K-factor transformers are specially designed to accommodate harmonic currents and offer protection against overheating caused by harmonics. They minimize harmonic current loss and have an additional thermal capacity of known limits. According to IEEE C57-110, the winding eddy current losses are considered proportional to the harmonic current squared times its harmonic number. K-factor is only an indicative value and the authors' main objective in this paper is to study the effect of harmonics on oil filled transformer and to simulate harmonic behavior using Matlab Simulink. A case study is simulated in order to investigate K-factor values with pumping loads, with and without the use of harmonic filters. Results are compared with measured values.

Authors and Affiliations

O. E. Gouda, G. M. Amer, W. A. A. Salem

Keywords

Related Articles

Case Study of Effectiveness Evaluation of Staff Training Courses in Refah Bank

One of the newest and most well-known train patterns for evaluating the effectiveness of in-service staffs training is Kircpatrick model. In this paper, the effectiveness of staff training courses of Refah-bank is evalua...

Relevance and Applicability of Multi-objective Resource Constrained Project Scheduling Problem: Review Article

Resource-Constrained Project Scheduling Problem (RCPSP) is a Non Polynomial (NP) - Hard optimization problem that considers how to assign activities to available resources in order to meet predefined objectives. The prob...

Preventive Maintenance Interval Prediction: a Spare Parts Inventory Cost and Lost Earning Based Model

In this paper, some preventive maintenance parameters in manufacturing firms were identified and used to develop cost based functions in terms of machine preventive maintenance. The proposed cost based model considers sy...

Velocity Boundary Layer Analysis of a Flat Plate Heat Exchanger in Laminar Flow: A Case Study

In this article, a behavioral analysis of velocity boundary layer in a flat plate heat exchanger in laminar flow condition through CFD simulation using FLUENT software is done. The main objective of this study is to dete...

The “Stick-Slip” Phenomenon During the Active Earth Pressure Failure of a Granular Soil of Analogical Material

The aim of this paper is to highlight the "stick-slip" phenomenon in the mechanisms of failure related to active earth pressure of an analogical material simulating a granular medium. For this, a two-dimensional small-s...

Download PDF file
  • EP ID EP84802
  • DOI -
  • Views 306
  • Downloads 0

How To Cite

O. E. Gouda, G. M. Amer, W. A. A. Salem (2011). A Study of K- Factor Power Transformer Characteristics by Modeling Simulation. Engineering, Technology & Applied Science Research, 1(5), -. https://europub.co.uk/articles/-A-84802