Acoustic conditions in open plan offices – Pilot test results

Journal Title: Medycyna Pracy - Year 2016, Vol 67, Issue 5

Abstract

Background: The main source of noise in open plan office are conversations. Office work standards in such premises are attained by applying specific acoustic adaptation. This article presents the results of pilot tests and acoustic evaluation of open space rooms. Material and Methods: Acoustic properties of 6 open plan office rooms were the subject of the tests. Evaluation parameters, measurement methods and criterial values were adopted according to the following standards: PN-EN ISO 3382- 3:2012, PN-EN ISO 3382-2:2010, PN-B-02151-4:2015-06 and PN-B-02151-3:2015-10. Results: The reverberation time was 0.33– 0.55 s (maximum permissible value in offices – 0.6 s; the criterion was met), sound absorption coefficient in relation to 1 m2 of the room’s plan was 0.77–1.58 m2 (minimum permissible value – 1.1 m2; 2 out of 6 rooms met the criterion), distraction distance was 8.5–14 m (maximum permissible value – 5 m; none of the rooms met the criterion), A-weighted sound pressure level of speech at a distance of 4 m was 43.8–54.7 dB (maximum permissible value – 48 dB; 2 out of 6 rooms met the criterion), spatial decay rate of the speech was 1.8–6.3 dB (minimum permissible value – 7 dB; none of the rooms met the criterion). Conclusions: Standard acoustic treatment, containing sound absorbing suspended ceiling, sound absorbing materials on the walls, carpet flooring and sound absorbing workplace barriers, is not sufficient. These rooms require specific advanced acoustic solutions. Med Pr 2016;67(5):653–662

Authors and Affiliations

Witold Mikulski

Keywords

Related Articles

Structural empowerment and work–family fit in nurses

Background: The goal of the study was to investigate the relationship between structural empowerment and work–family fit in Polish nurses. Structural empowerment is a strategy for managing by providing the employees with...

The association between the Mediterranean diet and high physical activity among the working population in Croatia

Background: Unhealthy eating habits and physical inactivity constitute an emerging public health problem. The working population is of special interest for public health monitoring and evaluation because workers’ unhealt...

Severe facial reaction to thiurams in surgeons

Contact dermatitis is a major problem in the healthcare environment and in other sectors. Healthcare professionals may be exposed to a large number of chemical agents, including the accelerators for rubber vulcanization...

Occupational cancers – Epidemiology and certification

The etiology of cancer is multifactorial. Malignant tumors caused by factors occurring in the work environment, classified as carcinogenic in humans, can be recognized as an occupational disease. Analysis of epidemiologi...

Download PDF file
  • EP ID EP282776
  • DOI 10.13075/mp.5893.00425
  • Views 152
  • Downloads 0

How To Cite

Witold Mikulski (2016). Acoustic conditions in open plan offices – Pilot test results. Medycyna Pracy, 67(5), 653-662. https://europub.co.uk/articles/-A-282776