Active Personal Dosimeter in a Nuclear Medicine Center in Yazd City, Iran
Journal Title: Journal of Biomedical Physics and Engineering - Year 2011, Vol 1, Issue 1
Abstract
Introduction: Active personal dosimeters (APDs) are well accepted as useful and reliable instruments for individual dosimetry measurements. APDs have many advantages compared with passive dosimeters for individual external radiation dose assessments. In routine monitoring, occupational exposure is carried out for verification and demonstration of compliance with the regulatory dose limits. So, it is one of the most important tools in order to achieve or demonstrate the level of radiation protection. Methods: Yazd province has only one private nuclear medicine (NM) center. In this center, two NM technologists exposed to radioactive patients during radiopharmacuticals preparation were monitored. NM technologists have to be close to the patient during radiopharmaceutical injection and patient positioning on the gamma camera table. An electronic personal dosimeter DKG-21 Ecotest made in Ukraine which records the ambient dose equivalent rate and equivalent dose was used to monitor the radiation exposure to the technologists and to record the accumulation dose in mSv throughout a working day. This study was accomplished between the time period of January to June 2011. The dosimeter is designed to measure individual equivalent dose Hp(10). The dose range of gamma radiation was 0.01 mSv to 1 Sv and the energy range 0.05 to 6 MeV which was suitable for NM procedures. The planar and tomography NM images were performed by the 2 technologists in the morning and afternoon shifts. Results: The average monthly occupational dose of each technologist was approximately 0.6 mSv. Their annual doses were 6.6 and 8.8 mSv, respectively. They were lower than the maximum permissible dose of 20 mSv/y. Total number of NM procedures performed in this NM center during June 2010 to June 2011 was 3265. Conclusion: The use of APD for monitoring the NM technologists is a useful tool to check compliance with regulatory dose limits and radiation protection principals.
Authors and Affiliations
F. Bouzarjomehri, V. Tsapaki
Updating the Planar Patterson- Parker Table for Ir-192 and Cs-137 Brachytherapy Sources Using the Most Recent TG-43U1 Recommended Dosimetric Parameters
Background: The Patterson-Parker table was created in 1934 to determine mg-hr required to deliver the prescribed dose to the treatment area. These tables were created using the dosimetric data for 226Ra that was determin...
Synergistic Effects of NDRG2 Overexpression and Radiotherapy on Cell Death of Human Prostate LNCaP Cells
Background: Radiation therapy is among the most conventional cancer therapeutic modalities with effective local tumor control. However, due to the development of radio-resistance, tumor recurrence and metastasis often oc...
Dose Calculation Accuracy of Radiotherapy Treatment Planning Systems in Out-of-Field Regions
NO ABSTRACT
A Monte Carlo Study on the Effect of Various Neutron Capturers on Dose Distribution in Brachytherapy with 252Cf Source
Background: In neutron interaction with matter and reduction of neutron energy due to multiple scatterings to the thermal energy range, increasing the probability of thermal neutron capture by neutron captures makes dose...
A Framework for Optimal Attribute Evaluation and Selection in Hesitant Fuzzy Environment Based on Enhanced Ordered Weighted Entropy Approach for Medical Dataset
Background: In this paper, a generic hesitant fuzzy set (HFS) model for clustering various ECG beats according to weights of attributes is proposed. A comprehensive review of the electrocardiogram signal classification a...