Active Personal Dosimeter in a Nuclear Medicine Center in Yazd City, Iran
Journal Title: Journal of Biomedical Physics and Engineering - Year 2011, Vol 1, Issue 1
Abstract
Introduction: Active personal dosimeters (APDs) are well accepted as useful and reliable instruments for individual dosimetry measurements. APDs have many advantages compared with passive dosimeters for individual external radiation dose assessments. In routine monitoring, occupational exposure is carried out for verification and demonstration of compliance with the regulatory dose limits. So, it is one of the most important tools in order to achieve or demonstrate the level of radiation protection. Methods: Yazd province has only one private nuclear medicine (NM) center. In this center, two NM technologists exposed to radioactive patients during radiopharmacuticals preparation were monitored. NM technologists have to be close to the patient during radiopharmaceutical injection and patient positioning on the gamma camera table. An electronic personal dosimeter DKG-21 Ecotest made in Ukraine which records the ambient dose equivalent rate and equivalent dose was used to monitor the radiation exposure to the technologists and to record the accumulation dose in mSv throughout a working day. This study was accomplished between the time period of January to June 2011. The dosimeter is designed to measure individual equivalent dose Hp(10). The dose range of gamma radiation was 0.01 mSv to 1 Sv and the energy range 0.05 to 6 MeV which was suitable for NM procedures. The planar and tomography NM images were performed by the 2 technologists in the morning and afternoon shifts. Results: The average monthly occupational dose of each technologist was approximately 0.6 mSv. Their annual doses were 6.6 and 8.8 mSv, respectively. They were lower than the maximum permissible dose of 20 mSv/y. Total number of NM procedures performed in this NM center during June 2010 to June 2011 was 3265. Conclusion: The use of APD for monitoring the NM technologists is a useful tool to check compliance with regulatory dose limits and radiation protection principals.
Authors and Affiliations
F. Bouzarjomehri, V. Tsapaki
Radiation Exposure and Bell’s Palsy: A Hypothetical Association
Bell’s palsy is an idiopathic peripheral nerve palsy involving the facial nerve. It accounts for 60 to 75% of all cases of unilateral facial paralysis. The main mechanisms to induce BP remain unclear, but infection, isch...
Analysis of Relative Biological Effectiveness of Proton Beams and Iso-effective Dose Profiles Using Geant4
with proton beams in treatment planning systems (TPS) is of high significance. Given the significance of the issue and the studies conducted in the literature, this quantity is fixed and is taken as equal to 1.1. Objecti...
Use of Magnetic Resonance Imaging in Food Quality Control: A Review
ABSTRACT Modern challenges of food science require a new understanding of the determinants of food quality and safety. Application of advanced imaging modalities such as magnetic resonance imaging (MRI) has seen impressi...
Diagnosis of Tempromandibular Disorders Using Local Binary Patterns
Background: Temporomandibular joint disorder (TMD) might be manifested as structural changes in bone through modification, adaptation or direct destruction. We propose to use Local Binary Pattern (LBP) characteristics an...
Comparative Analysis of Neural Network Training Methods in Real-time Radiotherapy
Background: The motions of body and tumor in some regions such as chest during radiotherapy treatments are one of the major concerns protecting normal tissues against high doses. By using real-time radiotherapy techniq...