Comparative Analysis of Neural Network Training Methods in Real-time Radiotherapy
Journal Title: Journal of Biomedical Physics and Engineering - Year 2017, Vol 7, Issue 1
Abstract
Background: The motions of body and tumor in some regions such as chest during radiotherapy treatments are one of the major concerns protecting normal tissues against high doses. By using real-time radiotherapy technique, it is possible to increase the accuracy of delivered dose to the tumor region by means of tracing markers on the body of patients. Objective: This study evaluates the accuracy of some artificial intelligence methods including neural network and those of combination with genetic algorithm as well as particle swarm optimization (PSO) estimating tumor positions in real-time radiotherapy. Method: One hundred recorded signals of three external markers were used as input data. The signals from 100 markers thorough 10 breathing cycles of a patient treated via a cyber-knife for a lung tumor were used as data input. Then, neural network method and its combination with genetic or PSO algorithms were applied determining the tumor locations using MATLABĀ© software program. Results: The accuracies were obtained 0.8%, 12% and 14% in neural network, genetic and particle swarm optimization algorithms, respectively. Conclusion: The internal target volume (ITV) should be determined based on the applied neural network algorithm on training steps.
Authors and Affiliations
S Nouri, S M Hosseini Pooya, J Soltani Nabipour
Evaluating Gamma-H2AX Expression as a Biomarker of DNA Damage after X-ray in Angiography Patients
Objective: Coronary heart disease (CHD) is one of the most common diseases. Coronary angiography (CAG) is an important apparatus used to diagnose and treat this disease. Since angiography is performed through exposure to...
Manipulation Effect on Lumbar Kinematics in Patients with Unilateral Innominate Rotation and Comparison with Asymptomatic Subjects
Background: Lumbar motion analysis is used as a clinical method in the diagnosis and treatment of low back pain (LBP). So far, no studies have shown if manipulating the sacroiliac joint (SIJ) will change spinal kinematic...
Monte Carlo Study of Unflattened Photon Beams Shaped by Multileaf Collimator
Introduction: This study investigates basic dosimetric properties of unflattened 6 MV photon beam shaped by multileaf collimator and compares them with those of flattened beams. Materials and Methods: Monte Carlo simulat...
An Android Application for Estimating Muscle Onset Latency using Surface EMG Signal
Background: Electromyography (EMG) signal processing and Muscle Onset Latency (MOL) are widely used in rehabilitation sciences and nerve conduction studies. The majority of existing software packages provided for estimat...
Detection of Ultraweak Photon Emission (UPE) from Cells as a Tool for Pathological Studies
Objective: It is well-known that all living cells emit ultra-weak photon emission (UPE), which is due to byproducts of chemical reactions in cell metabolisms. It has been shown that Reactive Oxygen Species (ROS) in the c...