An Android Application for Estimating Muscle Onset Latency using Surface EMG Signal

Journal Title: Journal of Biomedical Physics and Engineering - Year 2019, Vol 9, Issue 2

Abstract

Background: Electromyography (EMG) signal processing and Muscle Onset Latency (MOL) are widely used in rehabilitation sciences and nerve conduction studies. The majority of existing software packages provided for estimating MOL via analyzing EMG signal are computerized, desktop based and not portable; therefore, experiments and signal analyzes using them should be completed locally. Moreover, a desktop or laptop is required to complete experiments using these packages, which costs. Objective: Develop a non-expensive and portable Android application (app) for estimating MOL via analyzing surface EMG. Material and Methods: A multi-layer architecture model was designed for implementing the MOL estimation app. Several Android-based algorithms for analyzing a recorded EMG signal and estimating MOL was implemented. A graphical user interface (GUI) that simplifies analyzing a given EMG signal using the presented app was developed too. Results: Evaluation results of the developed app using 10 EMG signals showed promising performance; the MOL values estimated using the presented app are statistically equal to those estimated using a commercial Windows-based surface EMG analysis software (MegaWin 3.0). For the majority of cases relative error <10%. MOL values estimated by these two systems are linearly related, the correlation coefficient value ~ 0.93. These evaluations revealed that the presented app performed as well as MegaWin 3.0 software in estimating MOL. Conclusion: Recent advances in smart portable devices such as mobile phones have shown the great capability of facilitating and decreasing the cost of analyzing biomedical signals, particularly in academic environments. Here, we developed an Android app for estimating MOL via analyzing the surface EMG signal. Performance is promising to use the app for teaching or research purposes.

Authors and Affiliations

R. Sharifian, M. Karimpour, H. Parsaei, Z. Rojhani-Shirazi, F. Yazdani

Keywords

Related Articles

Trunk Kinematic Analysis during Gait in Cerebral Palsy Children with Crouch Gait Pattern

Background: Deficits in upper body movement have received little attention during gait in cerebral palsy (CP) children with crouch gait pattern (CGP). Objective: Purpose of this research is to describe the correlation of...

An Aptamer-based Biosensor for Troponin I Detection in Diagnosis of Myocardial Infarction

Background: Acute myocardial infarction (MI) accounts for one third of deaths. Cardiac troponin I (TnI) is a reliable biomarker of cardiac muscle tissue injury and is employed in the early diagnosis of MI. Objective: In...

Effect of Exercise Training on Heart Rate Variability in Patients with Heart Failure After Percutaneous Coronary Intervention

Background: This study aims to evaluate the effect of exercise training on heart rate variability (HRV) and to determine the correlation between parameters of HRV and the ejection fraction in patients with heart failure...

Detection and Characterization of Human Teeth Caries Using 2D Correlation Raman Spectroscopy

Background: Carious lesions are formed by a complex process of chemical interaction between dental enamel and its environment. They can cause cavities and pain, and are expensive to fix. It is hard to characterize in viv...

Evaluation of Radiation Exposure Pattern and Radiation Absorbed Dose Resulting from Occupational Exposure of Anesthesiologists to Ionizing Radiation

Introduction: Little information is available concerning the radiation exposure of anesthesiologists, and no such data have previously been collected in Iran. This prospective study was performed to determine the amount...

Download PDF file
  • EP ID EP613522
  • DOI -
  • Views 137
  • Downloads 0

How To Cite

R. Sharifian, M. Karimpour, H. Parsaei, Z. Rojhani-Shirazi, F. Yazdani (2019). An Android Application for Estimating Muscle Onset Latency using Surface EMG Signal. Journal of Biomedical Physics and Engineering, 9(2), 243-250. https://europub.co.uk/articles/-A-613522