An Android Application for Estimating Muscle Onset Latency using Surface EMG Signal

Journal Title: Journal of Biomedical Physics and Engineering - Year 2019, Vol 9, Issue 2

Abstract

Background: Electromyography (EMG) signal processing and Muscle Onset Latency (MOL) are widely used in rehabilitation sciences and nerve conduction studies. The majority of existing software packages provided for estimating MOL via analyzing EMG signal are computerized, desktop based and not portable; therefore, experiments and signal analyzes using them should be completed locally. Moreover, a desktop or laptop is required to complete experiments using these packages, which costs. Objective: Develop a non-expensive and portable Android application (app) for estimating MOL via analyzing surface EMG. Material and Methods: A multi-layer architecture model was designed for implementing the MOL estimation app. Several Android-based algorithms for analyzing a recorded EMG signal and estimating MOL was implemented. A graphical user interface (GUI) that simplifies analyzing a given EMG signal using the presented app was developed too. Results: Evaluation results of the developed app using 10 EMG signals showed promising performance; the MOL values estimated using the presented app are statistically equal to those estimated using a commercial Windows-based surface EMG analysis software (MegaWin 3.0). For the majority of cases relative error <10%. MOL values estimated by these two systems are linearly related, the correlation coefficient value ~ 0.93. These evaluations revealed that the presented app performed as well as MegaWin 3.0 software in estimating MOL. Conclusion: Recent advances in smart portable devices such as mobile phones have shown the great capability of facilitating and decreasing the cost of analyzing biomedical signals, particularly in academic environments. Here, we developed an Android app for estimating MOL via analyzing the surface EMG signal. Performance is promising to use the app for teaching or research purposes.

Authors and Affiliations

R. Sharifian, M. Karimpour, H. Parsaei, Z. Rojhani-Shirazi, F. Yazdani

Keywords

Related Articles

Mandibular Trabecular Bone Analysis Using Local Binary Pattern for Osteoporosis Diagnosis

Background: Osteoporosis is a systemic skeletal disease characterized by low bone mineral density (BMD) and micro-architectural deterioration of bone tissue, leading to bone fragility and increased fracture risk. Since P...

Assessment of Adherence of Diagnostic Accuracy Studies Published in Radiology Journals to STARD Statement Indexed in Web of Science, PubMed & Scopus in 2015

Rationale and Objective: The objective of this study is to evaluate the methodological adherence of diagnostic accuracy studies published in radiology journals, which were indexed in different databases with the STARD st...

Diagnosis of OCD Patients Using Drawing Features of Bender Gestalt Shapes

Background: Since psychological tests such as questionnaire or drawing tests are almost qualitative, their results carry a degree of uncertainty and sometimes subjectivity. The deficiency of all drawing test is that the...

A New Potential Contrast Agent for Magnetic Resonance Imaging: Iron Oxide-4A Nanocomposite

Background: Magnetic resonance imaging (MRI) contrast agents have an important role to differentiate healthy and diseased tissues. Access and design new contrast agents for the optimal use of MRI are necessary. This stud...

The Influence of Brass Compensator Thickness and Field Size on Neutron Contamination Spectrum in 18MV Elekta SL 75/25 Medical Linear Accelerator with and without Flattening Filter: A Monte Carlo Study

Background: One of the most significant Intensity Modulated Radiation Therapy treatment benefits is a high target to normal tissue dose ratio. To improve this advantage, an additional accessory such as a compensator is u...

Download PDF file
  • EP ID EP613522
  • DOI -
  • Views 122
  • Downloads 0

How To Cite

R. Sharifian, M. Karimpour, H. Parsaei, Z. Rojhani-Shirazi, F. Yazdani (2019). An Android Application for Estimating Muscle Onset Latency using Surface EMG Signal. Journal of Biomedical Physics and Engineering, 9(2), 243-250. https://europub.co.uk/articles/-A-613522