Evaluation of Radiation Exposure Pattern and Radiation Absorbed Dose Resulting from Occupational Exposure of Anesthesiologists to Ionizing Radiation

Journal Title: Journal of Biomedical Physics and Engineering - Year 2017, Vol 7, Issue 3

Abstract

Introduction: Little information is available concerning the radiation exposure of anesthesiologists, and no such data have previously been collected in Iran. This prospective study was performed to determine the amount of radiation exposure of anesthesiologists for the purpose of assessing whether or not dangerous levels of radiation exposures were being reached, and to identify factors that correlate with excessive risk. Participants and Methods: The radiation exposure of all anesthesiology residents and the attending of Shiraz University of Medical Sciences during a 3-month period (from June to August 2016) was measured using a film badge with monthly readings. Physicians were divided into two groups: group 1 (the ones assigned to ORs with radiation exposure), and group 2 (the ones assigned to ORs with no or minimal radiation exposure). Results: A total number of 10744 procedures were performed in 3 major university hospitals including 353 cases of pediatric angiography, 251 cases of percutaneous nephrolithotomy, 43 cases of chronic pain palliation and 672 cases of orthopedic surgeries with C-arm application. In all 3 months, there were statistically significant differences in the amount of radiation exposure between the two groups. Conclusion: Anesthesiologists working in the cardiac catheterization laboratory, pain treatment service, orthopedic and urologic ORs are exposed to statistically significantly higher radiation levels compared to their colleagues in other ORs. The radiation exposure to anesthesiologists can rise to high levels; therefore, they should get proper teaching, shielding and periodic evaluations.

Authors and Affiliations

B Maghsoudi, S M J Mortazavi, S Khademi, P Vatankhah

Keywords

Related Articles

Comparative Analysis of Neural Network Training Methods in Real-time Radiotherapy

Background: The motions of body and tumor in some regions such as chest during radiotherapy treatments are one of the major concerns protecting normal tissues against high doses. By using real-time radiotherapy techniq...

Evaluation of the Effect of Source Geometry on the Output of Miniature X-ray Tube for Electronic Brachytherapy through Simulation

Objective: The use of miniature X-ray source in electronic brachytherapy is on the rise so there is an urgent need to acquire more knowledge on X-ray spectrum production and distribution by a dose. The aim of this resear...

A Monte Carlo Study on Dose Enhancement by Homogeneous and Inhomogeneous Distributions of Gold Nanoparticles in Radiotherapy with Low Energy X-rays

Background: To enhance the dose to tumor, the use of high atomic number elements has been proposed. Objective: The aim of this study is to investigate the effect of gold nanoparticle distribution on dose enhancement in t...

In-silico Evaluation of Rare Codons and their Positions in the Structure of ATP8b1 Gene

Background: Progressive familial intrahepatic cholestases (PFIC) are a spectrum of autosomal progressive liver diseases developing to end-stage liver disease. ATP8B1 deficiency caused by mutations in ATP8B1 gene encoding...

The Influence of Brass Compensator Thickness and Field Size on Neutron Contamination Spectrum in 18MV Elekta SL 75/25 Medical Linear Accelerator with and without Flattening Filter: A Monte Carlo Study

Background: One of the most significant Intensity Modulated Radiation Therapy treatment benefits is a high target to normal tissue dose ratio. To improve this advantage, an additional accessory such as a compensator is u...

Download PDF file
  • EP ID EP331777
  • DOI -
  • Views 86
  • Downloads 0

How To Cite

B Maghsoudi, S M J Mortazavi, S Khademi, P Vatankhah (2017). Evaluation of Radiation Exposure Pattern and Radiation Absorbed Dose Resulting from Occupational Exposure of Anesthesiologists to Ionizing Radiation. Journal of Biomedical Physics and Engineering, 7(3), 271-278. https://europub.co.uk/articles/-A-331777