Advances in Metered Dose Inhaler Technology: Hardware Development

Journal Title: AAPS PharmSciTech - Year 2014, Vol 15, Issue 2

Abstract

Pressurized metered dose inhalers (MDIs) were first introduced in the 1950s and they are currently widely prescribed as portable systems to treat pulmonary conditions. MDIs consist of a formulation containing dissolved or suspended drug and hardware needed to contain the formulation and enable efficient and consistent dose delivery to the patient. The device hardware includes a canister that is appropriately sized to contain sufficient formulation for the required number of doses, a metering valve capable of delivering a consistent amount of drug with each dose delivered, an actuator mouthpiece that atomizes the formulation and serves as a conduit to deliver the aerosol to the patient, and often an indicating mechanism that provides information to the patient on the number of doses remaining. This review focuses on the current state-of-the-art of MDI hardware and includes discussion of enhancements made to the device’s core subsystems. In addition, technologies that aid the correct use of MDIs will be discussed. These include spacers, valved holding chambers, and breath-actuated devices. Many of the improvements discussed in this article increase the ability of MDI systems to meet regulatory specifications. Innovations that enhance the functionality of MDIs continue to be balanced by the fact that a key advantage of MDI systems is their low cost per dose. The expansion of the health care market in developing countries and the increased focus on health care costs in many developed countries will ensure that MDIs remain a cost-effective crucial delivery system for treating pulmonary conditions for many years to come.

Authors and Affiliations

Stephen W. Stein, Poonam Sheth, P. David Hodson, Paul B. Myrdal

Keywords

Related Articles

Evaluation of Extractables in Processed and Unprocessed Polymer Materials Used for Pharmaceutical Applications

Polymeric materials are often used in pharmaceutical packaging, delivery systems, and manufacturing components. There is continued concern that chemical entities from polymeric components may leach into various dosage fo...

Disintegration Mediated Controlled Release Supersaturating Solid Dispersion Formulation of an Insoluble Drug: Design, Development, Optimization, and In Vitro Evaluation

The objective of this study was to develop a solid dispersion based controlled release system for drug substances that are poorly soluble in water. A wax-based disintegration mediated controlled release system was design...

Solid-State Interactions at the Core-Coat Interface: Physicochemical Characterization of Enteric-Coated Omeprazole Pellets Without a Protective Sub-Coat

Conventionally, scanning electron or transmission microscopy, Raman and near infrared (NIR) spectroscopy, terahertz, florescence, and nuclear magnetic resonance imaging have been used to characterize functional coating s...

Ampicillin Nanoparticles Production via Supercritical CO2 Gas Antisolvent Process

The micronization of ampicillin via supercritical gas antisolvent (GAS) process was studied. The particle size distribution was significantly controlled with effective GAS variables such as initial solute concentration,...

Construction and Validation of Binary Phase Diagram for Amorphous Solid Dispersion Using Flory–Huggins Theory

Drug–polymer miscibility is one of the fundamental prerequisite for the successful design and development of amorphous solid dispersion formulation. The purpose of the present work is to provide an example of the...

Download PDF file
  • EP ID EP682387
  • DOI  10.1208/s12249-013-0062-y
  • Views 79
  • Downloads 0

How To Cite

Stephen W. Stein, Poonam Sheth, P. David Hodson, Paul B. Myrdal (2014). Advances in Metered Dose Inhaler Technology: Hardware Development. AAPS PharmSciTech, 15(2), -. https://europub.co.uk/articles/-A-682387