ANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION

Abstract

An analysis of the electrostatic field of a cable twisted shielded pair for various types of test voltage: symmetric bipolar, unipolar and asymmetric is carried out. Voltage selection affects the location of the most probable place of arising of the partial discharges, phase characteristics of which are used for technical diagnostics of insulation.

Authors and Affiliations

A. V. Bezprozvannych, A. G. Kyessaeyv

Keywords

Related Articles

NUMERICAL ESTIMATES OF ELECTRODYNAMICS PROCESSES IN THE INDUCTOR SYSTEM WITH AN ATTRACTIVE SCREEN AND A FLAT RECTANGULAR SOLENOID

Purpose. To carry out numerical estimates of currents and forces in the investigated inductor system with an attractive screen (ISAS) and determine the effectiveness of the force attraction. Methodology. The calculated r...

CHARACTERISTICS OF SPECIALIZED SINGLE-PHASE HIGH VOLTAGE DOUBLER RECTIFIER

Introduction. To obtain a high voltage direct current, voltage multipliers with a number of cascades of three or more are widely used. At the same time, for voltage levels of 100…200 kV there are several advantages of us...

DIELECTRIC SPECTROSCOPY OF CASING THERMOSETTING COMPOSITE ELECTRICAL INSULATION SYSTEM OF INDUCTION TRACTION ELECTRIC MACHINES

Introduction. Thermosetting composite electric insulation of traction electric motors undergoes significant heating, moisture, overvoltage, vibration. Purpose. The substantiation of the possibility of using dielectric sp...

ANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION

An analysis of the electrostatic field of a cable twisted shielded pair for various types of test voltage: symmetric bipolar, unipolar and asymmetric is carried out. Voltage selection affects the location of the most pro...

NEURO-SYSTEM OF AIMING AND STABILIZING WITH A REGULATOR ON THE BASIS OF STANDARD MODEL MODEL REFERENCE CONTROLLER

The aim of this work is the synthesis of neural network aiming and stabilization system for the special equipment of moving objects with neuro-controller on the basis of standard model and performance comparison of the n...

Download PDF file
  • EP ID EP301635
  • DOI 10.20998/2074-272X.2014.6.11
  • Views 83
  • Downloads 0

How To Cite

A. V. Bezprozvannych, A. G. Kyessaeyv (2014). ANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION. Електротехніка і Електромеханіка, 0(6), 61-65. https://europub.co.uk/articles/-A-301635