ANALYSIS OF THE FLAME PULSATION SIGNALS USING A SHORT-TIME FOURIER TRANSFORM

Abstract

The main aim of the diagnostics of combustion process is ensuring its stability and efficiency. The most important aspect related to the monitoring of the combustion process is a non-invasive acquisition of information from flame and subsequently subjecting it for further processing. Such method of research allows to evaluate the course of the process and determine the characteristic conditions under which the combustion process is stable or not. The article presents the application of short-time Fourier transform for the analysis of flame pulsation signals. The aim of the research was to find an area especially sensitive to the change of combustion process conditions.<br/><br/>

Authors and Affiliations

Żaklin Grądz

Keywords

Related Articles

CONTROL MODEL OF DATA STREAM TRANSMITTED OVER A NETWORK BASED ON PROXYING TECHNOLOGY

Network traffic control model is described in the work, including data mining modules transmitted in the network as well as further qualified data analysis module based on artificial intelligence methods and means, namel...

MANUFACTURING PLANNING AND CONTROL SYSTEM USING TOMOGRAPHIC SENSORS

The article presents an idea of a production process control system. Advanced automation and control of production processes play a key role in maintaining competitiveness. The proposed solution consists of sensor networ...

TECHNOLOGIA OPC JAKO NARZĘDZIE INTEGRACJI SYSTEMÓW ZAUTOMATYZOWANYCH

W artykule rozpatrzono możliwość zastosowania technologii OPC w systemach zautomatyzowanych. Dokonano przeglądu tej technologii, a także określono perspektywy jej rozwoju.

METHODS FOR DETECTION ANALYSIS IN QUALITY CONTROL SYSTEM

The article contains a description of the quality control system based on optical detection algorithms. It plays an increasingly important in the production process. The development of new systems based on the technology...

ANALIZA PRZYPŁYWU WIROWEGO Z ZASTOSOWANIEM ELEKTRYCZNEJ TOMOGRAFII POJEMNOŚCIOWEJ

W artykule opisano zastosowanie dwupłaszczyznowego systemu elektrycznej tomografii pojemnościowej (ECT) do pomiaru przepływów wirowych materiałów sypkich. W artykule zaprezentowano metodę wyznaczania składowej kątow...